Rear or bottom
piping
1) Place the refrigerant piping and the drain hose together, then firmly apply piping tape (G)
from the end.
2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the upper
part of the indoor unit on the installation
plate (1).
3) Check if the indoor unit is attached securely on the installation
plate (1) by moving the
unit to left and right.
4) Attach the lower part of the indoor unit into the installation
plate (1).
/
Cut off in case of down-
ward piping.
Right piping
Note:
Before performing the following, make sure that wiring is completed,
and the conduit cover
is installed. (Refer to 2-3.)
1) Place the refrigerant
piping and the drain hose together,
shift them to left side of the
unit, and then firmly apply piping tape (G) from the end.
2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the upper
part of the indoor unit on the installation
plate (1).
3) Check if the indoor unit is attached securely on the installation
plate (1) by moving the
unit to left and right.
4) Attach the lower part of the indoor unit into the installation
plate (1).
2-5-2.
DRAIN
PiPiNG
If the extension
drain hose has to pass through a room, be sure to wrap it with in-
sulation
(field-supplied).
• The drain hose should point downward for easy drain. (Fig. 1)
If the drain hose provided with the indoor unit is too short, connect it with a field-
supplied drain hose (I). (Fig. 2)
• When connecting
the drain hose to a hard vinyl chloride pipe, be sure to insert it
securely into the pipe. (Fig. 3)
O
Downward
slope
Soft hose I.D.
19/32 in.
(15 mm)
Fig. 1
Fig. 2
27-9/16 in.
70% i
Different
_'_[
diameter joint
Drain hose
t.D. 1-3/16 in.
Fig. 3
[_Do not make drain _as
shown below,
i
At least
1-31/32 in.
drain water
,Air
'end _ g5Op mm)
Water
Water
Water
[_):
leakage
leakage
Waving
leakage _
Ditch
3=1. CONNECTING WIRES FOR OUTDOOR UNIT
t) Remove the service panel.
2) Remove the conduit cover.
3) Attach the conduit connector
to conduit cover with lock nut then secure it against unit
with screws.
4) Connect ground wires of indoor/outdoor
unit connecting
wire (A) and power supply cord
(K) to the TB support.
5) Loosen the terminal screw, and attach indoor/outdoor
unit connecting
wire (A) from the
indoor unit correctly
on the terminal block. Attach the wire to the terminal block securely
so that its core cannot be seen, and no external force affects the connecting
section of
the terminal block.
6) Firmly tighten the terminal screws. After tightening,
verify that the wires are tightly fas-
tened.
7) Connect power supply cord (K).
8) Install the conduit cover.
9) Install the service panel securely.
5/8 in.
1-3/8 in.
I
_____
(15 mm)
(35 Lead
mm)__
_
Power supply
cord (K)
Service
panel
Grounding
terminal
Lock nut
Conduit cover
Connector
Terminal block
TB support
_
Power supply cord (K)
Indoor/outdoor
unit
connecting
wire (A)
to conduit cover
I
ake ground wire a little longer than oth-
ers. (More than I-3/8 in. [35 mm])
For future
servicing,
leave some slack in
the connecting wires.