Connecting The Power; Additional Grounding Procedure; Grounding Instruction; Connecting The Water - Thermador T361T71FNS Installation Instructions Manual

Built-in refrigerators, freezers and wine units
Table of Contents

Advertisement

Available languages

Available languages

iiiiiiiii
Connecting
the power
Electrical Shock Hazard
-
Plug into a grounded 3 prong outlet.
-
Do not remove ground prong.
-
Do not use an adapter.
-
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
The appliance comes with a 3-wire power supply cord,
UL listed in the USA.
The appliance requires a 3-wire receptacle.
The receptacle must be installed by a licensed electrician
only.
The receptacle must be fitted with a 10 A fuse or higher.
Please observe in this coherence the following table:
Appliance
Maximum load at one time
Bottom Freezer 36"
6 Ampere
Connecting
the water
A cold water connection is required for operation of the
automatic ice maker. The water pressure must be between
25 and 120 p.s.i. (1.72-8.25 bar). The installation must
comply with local plumbing regulations.
A separate shut-off valve must be installed for the appliance
water connection.
The shut-off valve for the water connection must not be
behind the appliance. It is recommended to place the shut-
off valve directly next to the appliance (base unit) or in another
easily accessible location.
When installing the water connection, observe the permitted
installation areas for the pipe. For the permitted installation
areas and dimensions see "installation dimensions", page 9.
The supply pipe can be located at the side on the right (a),at the
side on the left (b) or underneath (c), page 9.
Maximum outer diameter of
the water pipe (without fittings):
13/32"
(10 rnrn).
Attach a separate shut-off valve for the water connection in a
suitable, easily accessible location. Do not use a self-piercing
valve!
Orient ground prong to the bottom as shown in the pictures.
For the installation position of the receptacle see "installation
dimensions", page 9.
Additional
grounding
procedure
Some local regulations may require a separate ground. In
such cases, the required accessory ground wire, clamp and
screw must be purchased separately.
Never ground the appliance to plastic plumbing lines, gas
lines or water pipes.
Grounding
instruction
This appliance must be grounded. In the event of
a malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for the
electric current.
Improper connection of the equipment grounding
conductor may result in electric shock. Have the
appliance checked by a qualified electrician or service
technician if you are in doubt as to whether the
appliance has been properly grounded.
8

Advertisement

Table of Contents
loading

Table of Contents