Unit Environment and Operating Conditions

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure,
and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude
( unpressurized)
*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight.
Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

Power Supply

Standard Efficiency
High
Efficiency*
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
Range
Rated Input Current
Rated Input Current with
Energy
Efficient*
Power Supply
Current Leakage
(NFPA 99)
Power Supply Fan
Power Cord Length
External Power Adapter
Dimensions
Total Cord Length
*High efficiency power supply is a requirement for ENERGY STAR qualification in conjunction with a select range of processors and
modules
Operating: 50° to 95° F (10° to 35°
Non-operating: –22° to 140° F(–30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
Ultra Slim Desktop
N/A
135W active PFC
87% efficient
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
N/A
2.4A
< 250 µA
N/A
N/A
6.7 x 2.6 x 1.5 in
12 ft 8 in
DA - 13424 North America — Version 28 — October 19, 2011
HP Compaq 8000 Elite Series
C)*
Small Form Factor
240W active PFC
240W active PFC
87/89/85% efficient at
20/50/100% load
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
4A
4A
< 275 µA
92mm variable speed
6 ft (1.83 m)
N/A
N/A
Convertible Minitower
320W active PFC
320W active PFC
87/89/85% efficient at
20/50/100% load
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
5.5A
5.5A
< 450 µA
92mm variable speed
6 ft (1.83 m)
N/A
N/A