HS1250 maintenance procedures consist of window cleaning and
window replacement.
C
LEANING
The scanner actually has two windows; upper and lower. While the top of
the upper scan window may require periodic cleaning due to spillage,
surface dust, etc., other window surfaces are unlikely to need much atten-
tion. In the event you do need to clean them, here's how:
ALCOHOL
or
ACETONE
Reference the illustrations on page 25.
1. Insert a coin into the slot along the scanner's edge
and use it to gently pry the top cover from the
scanner.
2. Spray ordinary glass cleaner onto a lint free, nonabrasive
cleaning cloth.
3. Gently wipe the underside of the upper window.
4. Clean the top surface of the lower window as needed.
5. Reinstall the top cover, inserting the alignment tabs in
their respective slots. Press down along all edges to seat.
6. Clean the upper window top surface as described above.
This completes the window cleaning instructions.
24
R
OUTINE
NOTE
Although the scanner windows are
made of high quality, scratch resis-
tant glass, they should not be sub-
jected to abrasive cleaners or pads.
Additionally, do not use alcohol or
acetone.