Installation:
1. Insert window sash seal behind the top of the lower window sash and against
the glass of the upper window (FIG. 15).
2. Place the window-lock bracket on top of lower window and against upper
window sash on right side of the window (FIG. 15).
3. Use a 3/32" drill bit to drill starter holes through the holes in the bracket into
the window sash (FIG.15).
4. Attach the window lock-bracket to the window sash with two #10 X 1/2"
round-head screws to secure window in place (FIG.15).
5. Insert air conditioner into cabinet (FIG.16).
6. Reconnect electronics plug if present. Insert front tabs of front panel into top of
cabinet and swing front into place (FIG.17A).
7. Attach bottom front of panel with front panel screws (FIG.17B).
8. Plug into a grounded 3 prong outlet.
9. Press RESET on the power supply cord.
FIG.16
FIG.17A
FIG.17B
FIG.15
B
D
A. Window lock bracket
B. Upper window glass
C. Window sash seal
D. #10Xl/2"
round-head
_
I1[ _
/
electronics plug
_ _-_-_:_-_2,___
Through-the-Wall
Cabinet
Installation:
Option 1--wood,
metal or plastic molding:
When using a wood, metal or plastic molding, the wood frame should line up with the inside wall as shown FIG.18.
Option 2--Plastered
wall with no molding:
If the plastered wall is to be flush with the cabinet and no molding is used, the wood frame must be set 112" (13mm).
into the inside wall FIG.19.
FIG.18
ABC
FIG.20
1'
_
c
t
A. 16" (40.6 cm)
C
B. 22-5/8" (57.5 cm)
C. Wood thickness
D. 2-1/2" (6.4 cm) minimum to
6-1/2"(16.5
cm) maximum
AB
C
FIG.19
_i ii
iiiii
A. Molding
C. Wood frame
A. Plastered wall
C. Wood frame
B. Inside wall
D. Louvers
B. Inside wall
D. Louvers
Install Wood Frame:
1. Construct the wood frame. See FIG.20 for dimensions.
2. Measure the outside width and height of frame to determine wall opening dimensions. The wall opening
measurements should be :
Width : 22-5/8" (57.5 cm) plus twice thickness of wood used to build frame.
Height: 16" (40.6 cm) plus twice thickness of wood used to build frame.
Depth : 2-1/2" (6.4 cm) minimum to 6-1/2" (16.5 cm) maximum.
3. Cut the opening through the wall. Remove and save insulation.
4. Apply the wood preservative to the outside exposed surface.
5. Insert the frame in the wall opening. Square and level frame.
6. Attach frame securely to the wall.