About Advanced Features & Operation
Heating
Deadband
Deadband
db 2
(non-adj. 2 )
2nd Stage
1st Stage
turn on
turn on
DECREASE
The above figure assumes the minimum on time for the prior stage
has been met to allow the next stage to turn on, once the deadbands
have been exceeded.
ELECTRIC HEAT - Selecting Electric Heat (step #6, page 7), will cause the
thermostat to turn on the fan immediately any time there is a heat
demand. Since most gas furnaces control the fan, this feature should be
off unless it is necessary for the thermostat to energize the fan with first
stage heat.
EMERGENCY HEAT - Only available if you have a Heat Pump
installed. To initiate the Emergency Heat feature, press the FAN
button. While holding the FAN button press
Cool setpoint display will read 'EH' (emergency heat).
Press for
Emergency Heat
FAN
Operation - During Emergency Heat operation the thermostat will turn on the
fan and the 2nd stage of heat when there is a demand for heat. Also
during Emergency Heat, the 1st stage of heating or cooling will be
unavailable.
Exit Emergency Heat - Follow the same steps as entering Emergency Heat
by pressing the FAN and UP buttons. During Emergency Heat, only OFF
and HEAT modes are available by pressing the MODE button.
Cooling
Deadband
Deadband
db 1
db 1
db 2
(adj. 1-6 )
(adj. 1-6 )
(non-adj. 2 )
1st Stage
Heat
Cool
turn on
Setpoint
Setpoint
TEMPERATURE
INCREASE
the
UP button. The
H
68
EAT
Page 11
2nd Stage
turn on