TOTALINE 1 For All Owner's Manual

TOTALINE 1 For All Owner's Manual

Programmable digital thermostat
Hide thumbs Also See for 1 For All:

Advertisement

OWNER'S MANUAL
1 For All
Programmable
Digital Thermostat
6:03
74
68
o
Am
O
1
CCUPIED
Su
C
OOL
68
H
EAT
o
TOTALINE
Meets California Title 24
*
Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage
Electric Cooling & Gas Heating, Heat Pump, Electric or Hydronic Heat.
TOTALINE
Commercial Systems & Services
P/N P374-2200
7 Day programmable
Pre-Programmed
Occupied Comfort
Unoccupied Energy
Savings
Auto Changeover
Easy To Read Display
Thermoglow
Backlight
*
Multi-Stage, One for All
3 Security Levels
Carrier Corporation 05/02

Advertisement

Table of Contents
loading

Summary of Contents for TOTALINE 1 For All

  • Page 1 OWNER'S MANUAL P/N P374-2200 1 For All Programmable Digital Thermostat 7 Day programmable Pre-Programmed Occupied Comfort 6:03 CCUPIED Unoccupied Energy Savings TOTALINE Auto Changeover Easy To Read Display Thermoglow Backlight Multi-Stage, One for All 3 Security Levels Meets California Title 24 Use with most Air Conditioning &...
  • Page 2: Table Of Contents

    Table Of Contents FRONT PANEL DISPLAY QUICK START Set the clock and go BASIC OPERATION PROGRAMMING Occupied / Unoccupied ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS.
  • Page 3: Front Panel

    Front Panel Backlit LCD Display 6:03 Warmer or + Button CCUPIED Cooler or - Button TOTALINE Override Button Heat or Cool Indicator Red = Heat, Green = Cool Programmable Thermostat 6:03 AUTO Mode Holiday Program Set Clock Override MODE HOLIDAY...
  • Page 4: Display

    Display i2 00 Program Setup Stop Start Locked unoccupied123 SuMTuWThFSa Service Filter Override AUTO Fan On Mode Indicators Selects the operation mode of the equipment. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies.
  • Page 5 Display Override Indication Indicates the current program is currently being overridden for up to 4 hours. Page 7,16. Occupied or Unoccupied Indication Indicates the program number: Occupied 1,2,3, or Unoccupied. Page 8-11. Setup Indication Indicates the thermostat is in the programming mode.
  • Page 6: Quick Start

    Quick Start Set the Clock and Go During Setup & Programming: SET CLOCK Pressing the Mode button Press the SET CLOCK selects different flashing items. button. (Represented in dark black) Pressing the Up and Down 12:00 buttons will modify the flashing Setup selection.
  • Page 7: Basic Operation

    Basic Operation Select Mode 12:00 The HEAT setting indicates the temperature the room has to reach before the furnace will Press turn on to heat the room. MODE 12:00 The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room.
  • Page 8: Select Desired Temperature

    Basic Operation Select Desired Temperature In any mode, adjust the desired Set Temperature 12:00 with AUTO buttons. Pressing the up/down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously. Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set temperature.
  • Page 9: Programming

    Programming Occupied & Unoccupied Periods Press PROGRAM Press the PROGRAM button to enter time period programming. occupied Select the maximum # of occupied periods to be used on any one day. Typically 1. (1,2 or 3) Press MODE occupied Adjust the cooling setpoint for occupied 1.
  • Page 10 Programming Occupied & Unoccupied Periods unoccupied Adjust the heating set- point for unoccupied periods. (35 - 99) Press MODE occupied Select the day for Occupied 1. (M - Su) Press MODE 7:00 Start Adjust the start time occupied for occupied 1. Press MODE 6:00...
  • Page 11 Programming Occupied & Unoccupied Periods The copy command becomes available after the maximum # of occupied periods are programed in a day. This example uses 1 as the maximum occupied periods ever programed in one day. Select Yes or No to copy the previous day’s program to this day.
  • Page 12 Programming Occupied & Unoccupied Periods Occupied Select Occupied 1 to run on this day (On), or not to run this day (Off). Press MODE Select Yes or No to copy the previous day’s program to this day. If No is selected: If Yes is selected: Selecting Yes, then pressing mode will copy the previous day’s program and then will ask the...
  • Page 13: Advanced Setup

    Advanced Setup NOTE: Each step # is located at Press the Mode button. the top right corner of the MODE While holding the Mode, display for easy reference. Steps 1 & 2 are accessed press the Program button PROGRAM by pressing Set Clock. to enter Setup screens.
  • Page 14 Advanced Setup Setup Adjust the minimum difference between cooling & heating setpoints. (0 - 6 ) Press MODE Select the cycles per Setup hour limit. d=cycles per hour limit defeated. d1=d + defeat 5 min. Compressor lockout. Press (d, d1, 2 - 6) MODE Setup Select the display back-...
  • Page 15 Advanced Setup Setup Select thermostat operation in degrees Fahrenheit or Centigrade. Press MODE Setup Select the security level: Locked 0=no security in effect 1=setpoint range limited 2=1+ program on all times 3=2 + prohibits setpoint Press changes MODE Setup Adjust the maximum Locked allowable heat setpoint when security is in effect.
  • Page 16: Advanced Setup Table

    Advanced Setup Advanced Setup Table Step # Description Range Factory Default Time of day clock set 24 hour 12:00 Am Day of the week Sun - Sat Monday Heat Pump Off / On Reversing Valve Polarity O / B Electric Heat Off / On Deadband or Temperature swing 1 - 6...
  • Page 17: About Advanced Operation

    About Advanced Features & Operation CLOCK BACKUP - In the event of a power loss, the thermostat internal clock will continue to keep proper time for a minimum of 48 hours without external power or batteries. 2 STAGE OPERATION - The 2nd Stage of heat or cool is turned on when (1) the 1st Stage has been on for a minimum of two minutes, and (2) the temperature spread from the setpoint is equal to or greater than: the setpoint...
  • Page 18 About Advanced Features & Operation ENERGY SAVING SMART FAN - If Fan On is selected, the fan will run continuously at all times,except in Off, and will only run if there is a heating or cooling demand in Unoccupied periods. EMERGENCY HEAT - To turn on Emergency Heat press in the Fan button.
  • Page 19 About Advanced Features & Operation ELECTRIC HEAT - Selecting Electric Heat on, page 13, step 6, will cause the thermostat to turn on the fan immediately any time there is a heat demand. Since all gas furnaces control the fan, this feature should be off unless the heater is only electric.
  • Page 20 About Advanced Features & Operation DUAL SETPOINT BEHAVIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming Occupied and Unoccupied periods, the thermostat will not allow the Heat setpoint to get closer to the Cool setpoint than the value programmed as the minimum difference in...
  • Page 21: Warranty

    Warranty One-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option, to replace any defective part will be provided without charge for the part itself;...