Fig. 14
These units are pre-tested at the factory with exactly 120
VAC, 60 Hz. They are checked and adjusted for firebox
tightness, gasket leakage, motor operation and igniter
operation. The Advance is then factory set at a mid-point
adjustment and in most cases will not need any adjustments.
NOTE: The factory low draft setting may not be correct
for the unit's permanent installation conditions.
The control board on the Advance is equipped with a low draft
adjustment port, located on the control face just to the right
of the igniter light. See Figure 14. This voltage adjustment
is provided to allow the unit to be adjusted for the household
voltage where the unit is going to be in permanent operation.
NOTE: The line voltage varies from area to area and often
home to home.
The low draft voltage should be adjusted to achieve the most
efficient burn on low burn or "maintenance". This voltage
adjustment allows the installer to change the low voltage
set point approximately 15 volts. This adjustment should
be done by the installer during set up because a draft meter
reading is required to insure proper set up.
If the unit is not adjusted properly, it does not cause a safety
concern. If the unit is adjusted too high, only efficiency is lost.
If the unit is adjusted too low, the low draft pressure switch
will not allow the feeder motor or the igniter to operate.
11

low draft voltage Adjustment

Combustion Motor
Speed Control
Low draft only set
point.
T h e s ma ll strai gh t
screwdriver slot is
plastic; therefore, the
unit can be adjusted
while in operation.
Draft Meter bolt
hole location
Fig. 15
A simple draft test should be performed after completing the
flue pipe installation. To record the results for future reference:
1. Plug unit into a 120 VAC, 60 HZ outlet.
2. Close the hopper lid, front view door, and the ash pan.
Neither pellets nor a fire are required for this test.
3. With the mode selector in the "OFF" position, turn the feed
adjuster to "TEST".
4. Record the high draft_____in W.C. (Normal is -.50 to
-.60) The control will be on the High Draft for a total of 2
minutes.
5. After 1 minute, the combustion motor will go down to low
draft and the distribution blower will go on high. Allow
approximately 15 seconds to pass for the combustion
motor to slow before checking the low draft.
6. If the low draft is between .35 and .45, record the reading
_____ in W.C. If the reading is higher, slowly turn the
set screw counter-clockwise until the draft lowers. If the
reading is lower, very slowly turn the set screw clockwise
until the draft increases.
NOTE: In some cases, the draft may not go as low as .35
even with the set screw completely counter-clockwise.