Electrical Connections; Electrical Requirements; To Make Electrical Connection - GE JSS28 Installation Instructions Manual

30" electric slide-in range
Hide thumbs Also See for JSS28:
Table of Contents

Advertisement

Installation
Instructions
ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS
CAUTION: For
p ersonal
safety,
do not use an extension
cord with this
appliance.
Remove
house fuse or open
circuit breaker
before
beginning
installation.
This appliance
must
be supplied
with the
proper
voltage
and frequency,
and connected
to an individual
properly
grounded
branch
circuit,
protected
by a circuit
breaker
or fuse
having
amperage
as specified
on the rating
plate.
The rating
plate
is located
above
the
storage
drawer
on the oven
frame.
We recommend
you
have the electrical
wiring
and hookup
of your
range
connected
by a
qualified
electrician.
After
installation,
have
the electrician
show
you where
your
main
range
disconnect
is located.
Check with
your
local
utilities
for electrical
codes which
apply
in your
area. Failure
to
wire
your
oven
according
to governing
codes
could
result
in a hazardous
condition.
If there
are no local codes,
your
range
must
be wired
and fused
to meet the requirements
of the
National
Electrical
Code, ANSI/NFPA
No. 70--
Latest
Edition.
You can get a copy
by writing:
National
Fire Protection
Association
Batterymarch
Park
Quincy,
MA
02269
Effective
January
1, 1996, the National
Electrical
Code requires
that new
construction
(not existing)
utilize
a 4-
conductor
connection
to an electric
range,
When
installing
an electric
range in new
construction,
follow
Steps
3 and 5 for 4-wire
connection,
You must
use a 3-wire,
single-phase
A.C.
208Y/120
Volt or 240/120
Volt, 60 hertz
electrical
system.
If the electrical
service
provided
does not
meet the above
specifications,
have
a
licensed
electrician
install
an approved
outlet.
TO MAKE ELECTRICAL
CONNECTION
• Remove
the junction
block
access
cover
(on range
back).
When
re-installing
one-piece
wire
cover,
make sure that wire
does
not become
pinched
between
wire
cover
and mainback.
All new constructions,
mobile
homes,
recreational
vehicle
and installations
where
local
codes
do not allow
grounding
through
neutral,
require
a four-wire
flexible
cord
kit.
If the range
is rated
between
8,750 and
16,500 watts,
a range
cord
kit rated for
40 amps
and a minimum
of 125/250
Volts
is required.
If the range
is rated
between
16,501 and 22,500 watts,
a range
cord
kit
rated
for 50 amps
and a minimum
of
125/250
Volts is required.
For existing
construction,
a three
wire
flexible
cord
kit
may be used, and the same
ratings
apply
as described
above.
• When
using
a cord
rated
40 Amps,
remove
the next to outermost
knockout
(1-3/8"
diameter)
in the connection
plate.
Likewise,
when
using
a cord
rated 50 Amps,
remove
the outermost
knockout
(1-3/4" diameter)
in the plate.
• Terminations
shall
be either
closed
loop
terminals
or open-end
spade
lugs with
upturned
ends. You must
use a clamp
or
strain
relief
to hold the cord.
6