Amana AGR6011VDW3 Installation Instructions Manual page 8

30" (76.2 cm) freestanding gas ranges
Hide thumbs Also See for AGR6011VDW3:
Table of Contents

Advertisement

!_ d_ __ ........
d'*_'¸ _ ............ @_ _ ,_
Explosion Hazard
Use a new CSA international
approved gas supply line.
install a shut=off valve.
Securely tighten alJ gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
3=
Use a 1%e"combination
wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
/
B
C
D
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter (must have Y2"male
pipe thread)
D. Flexible connector
E
H
G
F
E. Manual gas shutoff valve
F Y2" or 3/4"gas pipe
G. Use pipe-joint
compound.
H. Adapter
Complete
Connection
1. Check that the gas pressure regulator shutoff valve is in the
"on" position.
Typical rigid pipe connection
A combination
of pipe fittings must be used to connect the range
to the existing gas line. Your connections
may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound
made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
A
E
F
H
A. Gas pressure regulator
B. 90 ° elbow (must have
Y2" male pipe thread)
C. Nipple
D. Union
E. Black iron pipe
F Manual gas shutoff valve
G. Y2"or 3/4"gas pipe
H. Nipple
I. Union
J. 90 ° elbow
Typical flexible
connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
2=
3=
4.
A. Gas pressure regulator shutoff valve
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. If bubbles appear, a
leak is indicated. Correct any leak found.
Remove cooktop burner caps and grates from parts
package. Burner caps should be level when properly
positioned. If burner caps are not properly positioned,
surface burners will not light. Place burner grates over
burners and caps.
A. Burner base
B. Burner cap
C. Burner grate
8