Download Print this page

Amana AER5844VAW1 Installation Instructions Manual page 8

30" (76 cm) freestanding electric ranges
Hide thumbs Also See for AER5844VAW1:

Advertisement

3.
Feed the power supply cord through the strain relief on the
cord/conduit
plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
B
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the
cord/conduit
plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A
..................
B
4.
5.
6.
7.
A. Terminal block
B. Ground-link
screw
C. UL listed strain relief
D. Power supply cord wires
Use a Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw and ground-link section. The ground wire must be
attached first.
Use 3/8"nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
F
C
A. 10-32 hex nut
B. Ground-link
screw
C. Line 2 (red)
D. Green ground wire
E. Neutral (center) wire
F. Line 1 (black)
Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 13/8"(3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Tighten strain relief screws.
9. Replace terminal block access cover.
2.
3.
4.
A. Terminal block
B. Ground-link
screw
C. UL listed strain relief
D. Power supply cord wires - large opening
Use 3/8"nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
E
B
C
A. 10-32 hex nut
B. Line 2 (red)
C. Ground-link
screw
D. Neutral (white) wire
E. Line 1 (black)
Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 13/8"(3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5. Tighten strain relief screws.
6. Replace terminal block access cover.
8