Jenn-Air CVEX4270B20 Installation Instructions Manual page 4

20/30/45" (50.8/76.2/114.3 cm) electric downdraft cooktop
Hide thumbs Also See for CVEX4270B20:
Table of Contents

Advertisement

Available languages

Available languages

Cabinet Dimensions
A------t
G
A. 24" (61.0 cm) on 20" (50.8 cm) single cartridge models
30" (76.2 cm) on 30" (76.2 cm) double cartridge models
45" (114.3 cm) on 45" (114.3 cm) triple cartridge models
B. Combustible
area above countertop
(shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61 cm]
minimum
clearance if bottom of wood or metal cabinet is covered
by not less than 1/4"[0.6 cm] flame retardant millboard covered with
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended
upper cabinet depth
E. 2%" (5.4 cm) min.
F. 20%6" (58.2 cm)
G. 18" (45. 7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum
from bottom of
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand
side of cabinet
J. 1811/16 ' ' (47.5 cm) on 20" (50.8 cm) single cartridge models
307A6'' (77.3 cm) on 30" (76.2 cm) double cartridge models
413½='' (106.6 cm) on 45" (114.3 cm) triple cartridge models
K. Side clearance - See *NOTE.
L. 2" (5.1 cm) minimum clearance between back wall and countertop
cutout
*NOTE: Grills installed near a side wall must allow a minimum
clearance of 6" (15.2 cm) between cooktop and sidewall for
maximum performance.
Minimum clearance of 1" (2.5 cm) is
required to sidewalls and 3A" (1.9 cm) to rear wall.
NOTES: After making the countertop
cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification,
use a base cabinet
with sidewalls wider than the cutout.
Where possible, a 6" (15.2 cm) clearance is recommended
for
motor blower service. A minimum clearance of 1" (2.5 cm) is
recommended
to the sidewalls and a 3/4"(1.9 cm) clearance is
recommended
to the rear wall.
A minimum clearance of 2" (5.1 cm) is recommended
between the motor/blower
and cabinet for proper cooling.
A minimum clearance of 61/4 '' (15.9 cm) is recommended
for
removal of the grease container(s). Installed dimension for the
grease containers is 51/2"(14.0 cm).
For grills installed near a sidewall, a minimum clearance of
6" (15.2 cm) is recommended
between the cooktop and
sidewall for maximum performance.
Cutout Dimensions
A
I
A. 1811/16 ' ' + 1/16"
(47.5
cm
+_0.2 cm) on 20" (50.8 cm) single cartridge
models
307/16 '' + 1A6"(77.3 cm +_0.2 cm) on 30" (76.2 cm) double cartridge
models
413½='' + 1A6"(106.6 cm +_0.2 cm) on 45" (114.3 cm) triple
cartridge models
B. 209/16 '' +_1/16" ( 52.2 cm +_0.2 cm) maximum on all models
C. 6%6" (16.0 cm) on 20" (50.8 cm) single cartridge models
173/4" (45.1 cm) on 30" (76.2 cm) double cartridge models
173/4" (45.1 cm) on 45" (114.3 cm) triple cartridge models
D. 147/16 '' (36. 7 cm) on all models
E. 2%" (5.4 cm) minimum space to front edge of cooktop
F. Minimum
cabinet width:
21" (53.3 cm) on 20" (50.8 cm) single cartridge models
33" (83.8 cm) on 30" (76.2 cm) double cartridge models
45" (114.3 cm) on 45" (114.3 cm) triple cartridge models
G. Floor exhaust option
H. 6%" (15.6 cm) for 6" vent system
I. 6%6" (16.0 cm) on 20" (50.8 cm) single cartridge models
173/4" (45.1 cm) on 30" (76.2 cm) double cartridge models
173/4" (45.1 cm) on 45" (114.3 cm) triple cartridge models
J. 8" (20.3 cm) from center of the vent hole in the cabinet to the top
surface of the countertop,
on all models
K. Wall exhaust option
Do not terminate
the vent system
in an attic or other enclosed
area.
Use a Jenn-AiP
vent cap.
Vent system must terminate to the outside.
Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is
recommended.
For best performance,
do not use plastic or
metal foil vent.
Before making cutouts, make sure there is proper clearance
within the wall or floor for the exhaust vent.
Do not cut a joist or stud unless absolutely necessary. If a
joist or stud must be cut, then a supporting
frame must be
constructed.
The size of the vent should be uniform.
The vent system must have a damper. If roof or wall cap has a
damper, do not use damper supplied with the range hood.