COOKTOP SAFETY ........................................................................
1
INSTALLATION REQUIREMENTS
................................................ 2
Tools and Parts ............................................................................
2
Location Requirements ................................................................
2
Venting Requirements ..................................................................
4
Venting Methods ..........................................................................
5
Electrical Requirements
..............................................................
7
INSTALLATION
INSTRUCTIONS
..................................................
8
Prepare Cooktop ..........................................................................
8
Rotate Blower - Optional ..............................................................
8
Install Cooktop .............................................................................
9
Make Electrical Connection .......................................................
10
Complete Installation ..................................................................
11
SleCURITle DE LA TABLE DE CUISSON ................................. 12
EXIGENCES D'INSTALLATION ................................................
12
Outillage et pieces ...................................................................
12
Exigences d'emplacement ......................................................
12
Exigences concernant I'evacuation ........................................ 16
Methodes d'evacuation ...........................................................
17
Specifications electriques .......................................................
19
INSTRUCTIONS
D'INSTALLATION
.........................................
20
Preparation de la table de cuisson .........................................
20
Rotation du ventilateur - facultative ........................................ 20
Installation de la table de cuisson ........................................... 21
Raccordement electrique ........................................................
22
Achever I'installation ...............................................................
23
COOKTOP SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT
:
A conserver pour consultation par I'inspecteur local des installations 61ectriques.
W10421939A

Advertisement

Table of Contents
loading

Summary of Contents for Jenn-Air CVEX4270B20

  • Page 1 JENN-AIR° 20" (50.8 CM), 30" (76.2 CM) AND 45" (114.3 CM) ELECTRIC DOWNDRAFTCOOKTOP INSTALLATION INSTRUCTIONS INSTRL)CTIONSD'INSTALLATION DE LA TABLEDE CUISSON ELECTRIQUEAVEC ASPIRATION PARLEBASDE 20" (50,8 CM), 30" (76,2 CM) ET45" (114,3 CM) Tableof Contents/Tabledes mati_res COOKTOP SAFETY ................ SleCURITle DE LA TABLE DE CUISSON ......... 12 INSTALLATION REQUIREMENTS ..........
  • Page 2: Installation Requirements

    UL listed wire connectors • Metal ducting • Jenn-Air wall cap Jenn-AiP_6 '' (15.2 cm) Round Surface Wall Cap Damper Order Part Number A406 Jenn-AiP _31¼ '' x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper Order Part Number A403 To order, see the "Assistance...
  • Page 3 30" (76.2 cm) Double Cartridge Cooktop 45" (114.3 cm) Triple Cartridge Cooktop A. 3015A6 '' (78.6 cm) A. 46¼" (117.5 cm) B. 211/s'' (53.6 cm) B. 211/8'' (53.6 cm) C. Grease container C. Grease container D. Blower D. Blower o h l I D...
  • Page 4 Cabinet Dimensions Cutout Dimensions A------t A. 1811/16 ' ' + 1/16" +_0.2 cm) on 20" (50.8 cm) single cartridge (47.5 models 307/16 '' + 1A6"(77.3 cm +_0.2 cm) on 30" (76.2 cm) double cartridge models 413½='' + 1A6"(106.6 cm +_0.2 cm) on 45" (114.3 cm) triple cartridge models B.
  • Page 5: Venting Methods

    B. 6" (15.2 cm) round wall venting venting • Use a Jenn-Air ®vent cap for proper performance. If an alternate wall or roof cap is used, be certain the cap size is not reduced and that it has a backdraft damper.
  • Page 6 Concrete Slab Installations - Calculating Vent System Length Exhaust Through Window Well To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system....Vent Piece 6" (15.2 cm) Round 45 °...
  • Page 7 7. Reattach the four acorn nuts to secure the blower motor Example vent system assembly back to the blower exhaust scroll. wall cap 90 ° embow 6 ft (1.8 rn) 1- 90 ° elbow = 5 ft (1.5 m) 8 ft (2.4 m) straight = 8 ft (2.4 m) 1 - wall cap = 0 ft (0 m)
  • Page 8: Installation Instructions

    Before You Make the Electrical Connection: 4. Remove the removable grease filter by lifting the filter out. To properly install your cooktop, you must determine the type of 5. Using 2 or more people, remove the cooktop from the carton. electrical connection you will be using and follow the instructions 6.
  • Page 9 3. Insert the 3/8"socket and extension into the hole and use the ratchet handle to loosen the nut half of a rotation. Repeat this process for each of the four nuts. 1. Using 2 or more people, place cooktop right side up into the 4.
  • Page 10 !_ 4 ¸ _¢ _ E/_ _J_,_,_,_,,/i _,j_ 1. Disconnect power. 2. Remove wiring box cover from the cooktop plenum. 3. Remove the appropriate knockout for the size of the home power supply cable on the bottom side of the cooktop wiring box.
  • Page 11 1. Check that all parts are now installed. If there is an extra part, 6. Reconnect power. go back through the steps to see which step was skipped. 7. Use the Flow Tester Card provided with your cooktop to 2. Check that you have all your tools. check the airflow (see card for step-by-step instructions).
  • Page 12 I'installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous. Clapet de bouche de decharge murale & surface arrondie de 31¼"x 10" (8,3 x 25,4 cm) de Jenn-Air ® Outils n_cessaires Commander la piece numero A403 •...
  • Page 13 Dimensions du produit Module amovible pour table de cuisson 20" (50,8 cm) Module amovible double pour table de cuisson 30" (76,2 cm) \\\\\\\\\\ A. 19¼" (48,9 cm) B. 21 _" (53,6 cm) A. 30 r_" (78,6 cm) C. Contenant _ graisse B.
  • Page 14 Module amovible triple pour table de cuisson Dimensions du placard 45" (114,3 cm) A. 46¼" (117,5 cm) B. 21 _" (53,6 cm) C. Contenant _ graisse D. Ventilateur A. 24" (61,0 cm) sur les modeles _ module amovible unique de 20"...
  • Page 15 REMARQUES : Apres le decoupage de I'ouverture dans le plan Dimensions de I'ouverture _ d_couper de travail, il est possible que pour certaines configurations d'installation, il soit necessaire d'entailler les parois laterales du placard inferieur pour permettre le passage de la base de la table de cuisson.
  • Page 16: Methodes D'evacuation

    Pour les modeles electriques, un conduit metallique rond • Utiliser un clapet de conduit Jenn-Air ® pour que le rendement de 5" (12,7 cm) peut etre utilise pour une evacuation soit correct. Si une bouche de decharge murale ou de toit est directement depuis I'arriere de la table de cuisson &...
  • Page 17 Les methodes d'evacuation standard illustrees correspondent & Installations sur dalle de b_ton - Evacuation par un puits de fen6tre une table de cuisson avec aspiration par le bas montee sur comptoir. L'evacuation de la table de cuisson peut se faire par le mur ou le plancher.
  • Page 18 Exemple de circuit d'_vacuation Calcul de la Iongueur effective du circuit d'_vacuation bouche de d_charge murale Pour calculer la Iongueur effective du circuit d'evacuation 6pi(1,Sm) necessaire, additionner les Iongueurs equivalentes (pieds/m_tres) oo.°o °0° de tousles composants utilises dans le systeme. Composant Conduit de diam_tre...
  • Page 19 Revisser les quatre ecrous borgnes pour fixer le moteur du Pour obtenir un exemplaire des normes et codes ci-dessus, ventilateur a la volute d'evacuation du ventilateur. contacter : National Fire Protection Association One Batterymarch Park Quincy, MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 Avant d'_tablir la connexion...
  • Page 20: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION Determiner I'emplacement final de la table de cuisson. IMPORTANT : Les etapes supplementaires suivantes doivent _tre execut6es si le produit est installe dans une configuration d'eb6nisterie en peninsule ou en ilot. Au deballage, la spirale d'echappement du ventilateur est orientee vers I'arriere du placard, pour une evacuation &...
  • Page 21 4. Une fois les ecrous desserres, la spirale d'echappement ventilateur s'oriente sans effort vers le bas. A I'aide d'au moins 2 personnes, placer la table de cuisson dans I'ouverture en orientant la bonne surface vers le haut. REMAROUE : S"assurer que le bord avant de la table de cuisson est parall@le au bord avant du plan de travail.
  • Page 22: Raccordement Electrique

    C&ble _ 4 conducteurs depuis le point de distribution du domicile jusqu'au c&ble _ 4 conducteurs de la table de cuisson IMPORTANT : Utiliser le c&ble & 4 conducteurs provenant du point de distribution du domicile aux €:tats-Unis Iorsque les codes ne permettent pas la raise &...
  • Page 23 C&ble & 3 conducteurs depuis le point de distribution du Acheve/ cs on domicile jusqu'au c&ble & 4 conducteurs de la table de 1. Verifier que toutes les pieces sont maintenant installees. 8'il cuisson - E.-U. seulement reste une piece, passer en revue les differentes etapes pour decouvrir laquelle aurait et6 oubliee.
  • Page 24 W10421939A ©2011. 8/11 All rights reserved. @Registered TrademarkfrMTrademark of Jenn-Air, U.S.A. Used under license by Maytag Limited in Canada. Printed in U.S.A. Tous droits reserves. ®Marque deposeefrMMarque de commerce de Jenn-Air, U.S.A. Emploi sous licence par Maytag Limited au Canada.