Kenmore 790.71105892 Installation Instructions Manual page 6

30" gas range
Hide thumbs Also See for 790.71105892:
Table of Contents

Advertisement

Gas connection
for electric
ignition
models
Manual
Flare
Flexible
Flare Union
Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
Valve
|
Conduit
o ,a,
off
\
Service Shut-Off Valve Electric Ignition models only-_
(Shown in ON Position).
Besure lever is in the "On=position when
installation iscomplete
Gas connection
for pilot models
Manual
Flare
Flexible
Flare Union
Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
Valve
/
Conduit
I
off
a) Install an external
manual
gas shut-off
valve to gas
supply line in an easily-accessible
location outside of
the range. Be sure you know how and where to shut-
off the gas supply to the range.
b)
Install 1/2" flare union adapter to pressure regulator.
c)
Attach appliance conduit to flare union on regulator.
d)
Install flare union adapter to external manual
shut-off
valve.
e)
Attach appliance
conduit
to flare union on shut-off
valve.
f)
Make sure service shut-off
valve on pressure
regulator
is in "ON mposition.
g)
Check for leaks. Turn the gas supply on to the range and
use a liquid leak detector
at all joints
and conduits to
check for leaks in the system.
For an accurate pressure check have at least two (2) other
top burners burning. Be sure the gas supply (inlet) pressure
is at leastone inch above specified range manifold pressure.
The gas supply pressure should never be over 14 _ water
column.
When properly
adjusted for Natural Gas the
manifold pressure is 4/(For
LP/Propane Gas the manifold
pressure is 10.")
5.
Read
electrical
connection
details
below
and connect
electricity
to range.
Before
servicing,
disconnect
electrical
supply at circuit breaker,
fuse or power
cord.
Electric Reouirements: An individual, properly grounded
and polarized branch circuit protected by a 15 amp. circuit
breaker or time delay fuse. See serial plate for proper
voltage.
Extension Cord Precautions:
Because of potential safety hazardsunder certain conditions,
we strongly recommend against the use of any extension
cord. However, if you still elect to use an extension cord, it
is absolutely necessarythat it be a ULlisted 3-wire grounding
type appliance extension cord and that the current carrying
rating of the cord in amperes be equivalent to or greater
than the branch circuit rating. Such extension cords are
obtainable through your local service organization.
PLEASE READ CAREFULLY!
For personal
safety,
this product
must be properly
grounded.
Do not use a flame to check for gas leaks.
Checking
Manifold
Gas Pressure
Disconnect the range and its individual shut-off
valve from
the gas supply piping system during any pressure testing of
that system at test pressures
greater than 14" of water
column pressure (approximately
1/2" psig).
The appliance
must be isolated
from the gas supply piping
system
by closing
its individual
manual
shut-off
valve
during any pressure testing of the gas supply piping
system
at test pressures equal to or less than 14" of water column
pressure
(approximately
1/2" psig).
If it should
be necessary to check the manifold
gas pressu re,
connect
manometer
(water gauge) or other pressu re device
to the top burner
right
rear orifice.
Using a rubber
hose
with
inside
diameter
of approximately
1/4," hold tubing
down
tight over orifice.
Turn burner valve on.
5