MAINTENANCE INSTRUCTIONS

CAUTION:
Personal Injury
Hazard
Disconnect appliance from
electrical power before
cleaning condenser coil.
CAUTION:
Personal Injury
Hazard
Condenser coil fins are sharp.
Use care to avoid cuts while
cleaning the condenser.
CONDENSER COIL CLEANING INSTRUCTIONS
The condenser coil must be kept clean to allow adequate air flow for
proper heat dissipation. Recommend this procedure be performed
monthly.
1. Turn POWER SWITCH OFF. Disconnect unit from electrical
power.
2. Remove louvers or access panel to allow coil to be reached.
3. Using a stiff bristle brush, brush lint and debris from the condenser
fins. Brush vertically, top to bottom. Collect and discard all lint and
debris gathered from this operation
IMPORTANT: The fins of the condenser coil are delicate and
easily damaged. Use care to brush only in a vertical motion to
avoid damaging the coil fins.
4. Wipe the fan blades to remove accumulated lint.
5. Reconnect to electrical power. Test for proper operation.