Culligan Aqua-Cleer Owner's Manual page 42

Advanced drinking water systems
Table of Contents

Advertisement

Performance
Data Sheet
(con't)
42
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
Tank Size
Product System Daily Prod. Rate To Pressurized Storage
Tank
Prod. Rate without Storage Tank To Atmosphere
Efficiency Rating
2
Recovery Rating
3
Influent Challenge Concentration (Mg/L)
Max. Permissible Product Water Concentration (Mg/L)
Minimum Percent Removal
Average Percent Removal
1 This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on temperature, water pressure, TDS
level, membrane variation and usage pattern.
2 Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water under
operating conditions that approximate daily usage.
3 Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
Tank Size
Product System Daily Prod. Rate To Pressurized Storage
Tank
Prod. Rate without Storage Tank To Atmosphere
Efficiency Rating
2
Recovery Rating
3
Influent Challenge Concentration (Mg/L)
Max. Permissible Product Water Concentration (Mg/L)
Minimum Percent Removal
Average Percent Removal
1 This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on temperature, water pressure, TDS
level, membrane variation and usage pattern.
2 Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water under
operating conditions that approximate daily usage.
3 Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage tank or when the storage tank is bypassed.
*RO50 not for sale in California.
Testing Conditions (Complete System)
Temperature: 77º F + 2º F
Pressure: 50 psi
This system has been tested and shown to operate at its calculated recovery rating under
standard laboratory conditions.
This reverse osmosis system contains a replaceable component critical to the efficiency
of the system. Replacement of the reverse osmosis component should be with one of
identical specifications, as defined by the manufacturer, to assure the same efficiency and
contaminant reduction performance.
2 gallon
3 gallon
11.09 gpd
11.09 gpd
36 gpd
36 gpd
16.86%
16.86%
28.84%
28.84%
770
770
187
187
93.1%
93.1%
95.4%
95.4%
2 gallon
3 gallon
16.16 gpd
16.16 gpd
50 gpd
50 gpd
18.98%
18.98%
31.37%
31.37%
770
770
187
187
86.6%
86.6%
92.3%
92.3%
pH: 7.5 + 0.5
Turbidity: <1 NTU
– RO30
1
9 gallon
11.09 gpd
36 gpd
16.86%
28.84%
770
187
93.1%
95.4%
– RO50*
1
9 gallon
16.16 gpd
50 gpd
18.98%
31.37%
770
187
86.6%
92.3%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents