Culligan Aqua-Cleer Owner's Manual page 19

Advanced drinking water systems
Table of Contents

Advertisement

RO30
This system has been tested according to NSF/ANSI 58 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI 58.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L
nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite
reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.
Substance Reduction
1
Substance
Influent
Challenge
Concentration
mg/L
Arsenic (Pentavalent)
0.050 +/- 10%
2
Barium
10.0 +/- 10%
Cadmium
0.03 +/- 10%
Hexavalent Chromium
0.30 +/- 10%
Trivalent Chromium
0.30 +/- 10%
Copper
3.00 +/- 10%
Fluoride
8.0 +/- 10%
Lead
0.15 +/- 10%
Nitrate/Nitrite
30 +/- 10%
(both as N)
Nitrate
27.0 +/- 10%
5
Nitrite
3.0 +/- 10%
Radium 226/228
25pCi/L +/- 10%
3
Selenium
0.10 +/- 10%
Cyst
>50,000/mL
4
Turbidity
11 +/- 1 NTU
1 While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressure, temperatures and
other substances, which may be found in your water.
2 This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations
of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pen-
tavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent
arsenic. Please see the Arsenic Facts Sheet for further information.
3 Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.
4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
5 Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.
Maximum
Reduction
Permissible
Require-
Product
ments
water Con-
centration
mg/L
0.01
2
0.005
0.05
0.05
1.3
1.5
0.010
10.0
1.0
5pCi/L
0.05
99.95%
0.5 NTU
Minimum
Average
Reduction
Reduction
97.4%
98.3%
98.7%
91.2%
97.8%
98.9%
95.6%
98.7%
82.8%
86.4%
82.7%
86.5%
80.9%
84.7%
80.0%
96.0%
99.99%
99.99%
99.00%
Performance
Chapter
Data Sheet
Heading
(con't)
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents