Model UT30B/C/D/F: OPERATING MANUAL
E.General Specifications(1)
1. The maximum voltage, between any terminal and earth, is 600Vrms.
A . The"COM"input terminal is always connected with the black test
lead.
B . The"V mA"input terminal is always connected with the red test
lead and is used to measure voltage up to 500V,resistance and
current up to 200mA.
C . The"10A MAX"input terminal is always connected with the red test
lead and is used to measure current greater than 200mA but no
more than 10A.
2.
10A Terminal: non-fused
3.
mA Terminal Fuse:
4. Maximum Display is 1999,and updates two or three times every second.
5. Over range display is "1" or "OL". (Only UT30F).
5x20-315mA, 250V.(Fast)
ø