USE AND CARE Continued
120V SINGLE SWITCH
220-240V SINGLE SWITCH
4. Once the desired power switch(es) have been turned to
the "ON" position, the burners should ignite quickly. If
sparking continues and/or a burner does not light, shut
down power to the unit by turning the switch(es) to
the "OFF" position and wait 5 minutes before repeating
ignition. If ignition fails repeatedly, shut down power to
the unit and contact a qualified service technician.
5. It is recommended that the unit run for approximately 30
minutes on start up to reach the desired temperature.
6. For temperature adjustment, each burner has a control
knob which will adjust the height of the flame from a high
to a low position.
Page 10
LEFT SIDE
BURNERS
BURNERS
ON/OFF
ON/OFF
LEFT SIDE
BURNERS
BURNERS
ON/OFF
ON/OFF
MAIN
POWER
ON/OFF
$
120V DOUBLE SWITCH
220-240V DOUBLE SWITCH
7. To shut off the unit, the operator simply needs to turn off
the power switch(es). When shutting down for longer
periods of time, it is best to also close the manual shut-off
valve to the unit.
8. The cooking grates can be installed in 2 positions, to
provide flexibility when preparing different types of food.
To install the cooking grates in the standard position,
the rear feet on the grates should be placed through the
square cutouts on the rear wall of the broiler. To install the
cooking grates in the elevated position, the groove in the
feet of the grates should be placed on the top edge of the
rear wall of the broiler. Grates must be manually moved
from one position to another; and therefore, should be
moved when the grates are cool.