PROBLEM
Unit runs but produces very little ice. Dirty condenser coils
Poor ice quality (soft or unclear)
Unit produces shallow or incomplete
cubes, or the ice fill pattern on the
evaporator is incomplete.
Ice is slow to release or does not
release from the evaporator.
Ice storage bin full of water
Water leaking from under the unit
26
POSSIBLE CAUSE
High air temperature around unit
Scale and mineral buildup in unit
Inadequate airflow at the front of
the unit
Cleaning Cycle recently performed
Unit is not level.
Poor incoming water quality
Ice-making system is dirty.
Low water level
Hot incoming water
Incorrect incoming water pressure
Unit is not level.
Ice-making system is dirty.
Unit is not level.
Low air temperature around unit
Obstructed drain
Supply line leaking
Fill tube leaking
Bin drain leaking
CLR2160, CLRCO2175
REMEDY
Clean the condenser (See MAINTENANCE; CONDENSER
CLEANING).
Surrounding air temperature of over 90°F. Low ice
production at high temperatures is normal.
Run unit through self cleaning cycle (See
MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE.
Remove items blocking airflow.
Allow unit to reach the set temperature to produce ice
normally.
Level unit (See MAINTENANCE; LEVELING).
Consult a qualified plumber to test the water quality
and recommend appropriate treatment.
Run unit through self cleaning cycle (See
MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE).
Check to see that overflow tube is fully seated.
Connect the unit to a cold water supply.
Water pressure must be 20-120 psi.
Level unit (See MAINTENANCE; LEVELING).
Run unit through self cleaning cycle (See
MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE).
Level the unit (See MAINTENANCE: LEVELING).
Surrounding air temperature must be at least 50°F.
Check to see that storage bin drain opening is free from
obstruction and debris.
Tighten connection as required.
Check connection at water valve outlet.
Check integrity of bin drain hose and clamp.