MAIN BURNER FLAME CHARACTERISTICS

If pilot flame pattern is incorrect
• See Troubleshooting, page 16.
Main Burner Flame pattern
The main burner flame will be completely yellow.
Main Burner Flame Ignition and Extinction
When the main burner is ignited it will take a few seconds for the full flame pattern to develop.
When the main burner is extinguished it will take a few seconds for the flames to disappear. It is normal to have the flames burn down
near the burner, as the remaining gas is burned.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
1. Remove batteries (4) and battery pack from instruction envelope package.
2. Slide battery cover plate off of battery pack, insert batteries (ensure correct polarity), and replace battery cover plate.
3. Connect red wire from battery pack to red wire from valve.
4. Connect black wire from battery pack to red wire from valve.
5. Attach wire harness from control module to battery pack.
6. Place battery pack on raised section of firebox bottom through hole in burner bottom.
GAS CONTROL
VALVE
HI/LO
Solenoid
Page 16

WIRING

WHITE
ORANGE
PILOT
MAIN
PILOT
BLACK
(SENSOR)
ORANGE
(IGNITOR)
RED
BLACK
N/A
N/A
BROWN
GREEN
IPI
(GND)
ELECTRONIC
CONTROL MODULE
AF-4000 B/P
ORANGE
BLACK
POWER
RED
BROWN
32274-0-0713