The SAFETY LIGHT (model i12080 only) portion is powered by one (1) 9V alka-
line battery. Under normal (standby) conditions, the battery should last at least
one year and provide 15 minutes of pulsating light when the alarm is sounding.
NOTE: WEEKLY TESTING IS REQUIRED! If the Safety Light appears dim
during regular testing, replace both batteries immediately.
USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR FOR SAFETY LIGHT BAT-
TERY REPLACEMENT.
ENERGIZER 522; DURACELL MN1604,MX1604; GOLD PEAK 1604A
PANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61 (GA)
WARNING!! BE SURE TO FOLLOW BATTERY INSTALLATION INSTRUCTIONS
PRINTED ON THE INSIDE OF THE BATTERY DOOR AND USE ONLY THE
BATTERIES SPECIFIED. USE OF DIFFERENT BATTERIES MAY HAVE A DETRI-
MENTAL EFFECT ON THE SMOKE ALARM.
LAMP REPLACEMENT: The Safety Light uses a 6.3 volt 250mA fuse type lamp
which has an average life of 50 hours. If the Safety Light does not operate with
a fresh alkaline battery, replace the lamp. To replace the lamp, remove the alarm
from trim ring by following the ALARM REMOVAL instructions at the beginning
of this section. Open the battery door and remove both batteries from the unit.
Grip the lamp holder with your thumb and finger (see figure 10) and pull out
the lamp holder assembly (see figure 10A). Slide the old lamp out of the lamp
holder and replace it with a new lamp (see figure 10B).
FIGURE 10
Reinstall the lamp holder. It will snap easily into the base. Put working batteries
back in the alarm and remount the alarm on its mounting trim ring.
Replace with the correct lamp type; Vanco #FTB 6, available at most radio/tv
repair stores. The lamp is also available from KIDDE Safety, 1394 South Third
Street, Mebane, NC 27302. Send $1.50 (check or money order) and request a
i12080 replacement lamp.
FIGURE 10A
FIGURE 10B