READ AND SAVE THESE INSTRUCTIONS
®
Installation, Operation and Maintenance Manual
Prepare the Fan
1. Remove either top or side wiring knockout, depending on wiring direction, by
bending it back and forth to break tabs, shown in Fig. 1.
2. Check ductwork to see if the
fan's discharge requires rotation
from horizontal to vertical
discharge, shown in Fig. 2.
3. To rotate from horizontal to vertical discharge, remove the eight screws holding the cover panel as
shown in Fig. 3a (for the CSP model remove the eight collar screws as shown in Fig. 4a). Then rotate
the fan housing so the discharge is facing up, shown in Fig. 3b. Replace the cover panel as shown in
Fig. 3b and replace the screws (for the CSP model attach the collar and its screws as shown in Fig. 4b).
WARNING !
To reduce the risk of fire, electric shock, or injury to
persons, observe the following:
• If a speed controller is used, this fan should only
be used with fan speed control, manufactured by
KB Electronics, Inc.
• Before servicing or cleaning unit, switch power off
at service panel and lock service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
• Installation work and electrical wiring must be
done by qualified person(s) in accordance with all
applicable codes and standards, including fire-
rated construction.
• The combustion airflow needed for safe operation
of fuel burning equipment may be affected by this
unit's operation. Follow the heating equipment
manufacturer's guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local
code authorities.
• When cutting or drilling into wall or ceiling, do not
damage electrical wiring or other hidden utilities.
• Ducted fans must always be vented to the
outdoors.
• For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
• These fans are not recommended for cooking
exhaust applications. They are designed primarily
for low temperature, clean air applications only.
Model SP/CSP-A700
Ceiling Exhaust and Inline Fans
Airflow
Fig. 2
Access
Panel
Fig. 3a
Collar
Access
Panel
Fig. 4a
1
PN 464238
Knockouts
Electrical
Access
Panel
Fig. 1
Access
Panel
Fig. 3b
Collar
Access
Fig. 4b
Panel

Advertisement

loading

Summary of Contents for Greenheck CSP-A700

  • Page 1 • These fans are not recommended for cooking exhaust applications. They are designed primarily for low temperature, clean air applications only. Model SP/CSP-A700 Ceiling Exhaust and Inline Fans Airflow Fig. 2 Access Panel Fig.
  • Page 2: Installation Recommendations

    Installation Recommendations Ceiling Radiation Damper - CRD 1. If fan is to be used in a fire resistive membrane ceiling, a ceiling radiation damper must be used. Otherwise, proceed to Install the Fan. 2. If the ceiling radiation damper is already mounted to the fan from the factory, proceed to Install the Fan.
  • Page 3 Installation Recommendations Install the Fan - Continued 3. Installation of ductwork is critical to the performance of the fan, shown in Fig. 11. Straight ductwork (1) or ductwork that turns in the same direction as the wheel (2) is recommended. Ductwork turning opposite the wheel direction (3) will cause turbulence and back pressure resulting in poor performance.
  • Page 4 PH. 715-359-6171 ® www.greenheck.com Flex Duct Connections Remote Mounted SP and SP-C Mounted Directly Overhead Incorrect SP/CSP models shown are UL and cUL listed E 33599 SP/CSP-A700 IOM FS #464238 Rev 1 March 2004 Copyright © 2004 Greenheck Fan Corp.

This manual is also suitable for:

Sp-a700