Rack Information; Overview; Rails; Table 17. Supported Racks - Dell PowerEdge R210 II Technical Manual

Ultra-dense 1-socket 1u rack server
Hide thumbs Also See for PowerEdge R210 II:
Table of Contents

Advertisement

Dell

14 Rack Information

14.1 Overview

The ReadyRails™ static rail systems for the R210 II provide toolless support for racks with square or
unthreaded round mounting holes including all generations of Dell racks. The rail systems also offer
tooled mounting support for 4-post threaded and 2-post (Telco) racks for added versatility. See Table
17 for the list of supported rails and racks.

14.2 Rails

Two different static rail systems are available for the R210 II: the A4 rail system and the A6 rail
system. Both support toolless mounting in 19‖-wide, EIA-310-E compliant square hole and unthreaded
round hole racks using the ReadyRails™ mounting interface. Both also support a generic mounting
interface for tooled mounting in threaded hole and 2-post (Telco) racks. Screws are not included in
either kit because threaded racks are offered with a variety of thread designations.
Product
A4
R210 II
A6
The A6 rail system also supports a cantilever (ear) mounting option, although it is not recommended
since it does not support shipment of the server in the rack and allows the position of the server to
exceed its designated U-space.
The key difference between the A4 and A6 rail systems is the overall length of the rail members. The
A6 rail system, which is the default rail system being offered with the R210 II, is the shorter of the
two and is well suited for mounting in 2-post racks or in 4-post racks with mounting flanges that are
spaced in the 500-760 mm range. The A4 rail system is longer and can be used for mounting in 4-post
racks with mounting flanges that are spaced in the 600-890 mm range. See Table 18 for specific
adjustment range information on each rail system.
Rail
Product
ID
A4
R210 II
A6
1
With middle brackets removed
2
With rear brackets removed (applies to 2-post or cantilever mount only)
PowerEdge R210 II Technical Guide
Table 17.
Rail
Mounting Interface
ID
ReadyRails/Generic
ReadyRails/Generic
Table 18.
Rail Adjustability Ranges and Depth
Mounting
Rail
Interface
Type
ReadyRails/
Static
Generic
ReadyRails/
Static
Generic
Supported Racks
Rail
Type
Square
Static
Static
Rail Adjustability Range
(mm)
Square
Round
Min
Max
Min
Max
608
879
594
872
5081
751
4941
744
Rack Types Supported
4-Post
2-Post
Round
Thread
Flush
Rail Depth
Threaded
without
CMA
Min
Max
604
890
622
515
5191
762
376
Center
(mm)
with
CMA
1
2
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r310Poweredge r210

Table of Contents