5. ADJUSTMENT LOCATION AND PROCEDURE

A. ADJUSTMENT
NOTE: Prior to adjustment of actuation arm or trip lever,
always check the reservoir mounting wing nuts on the
bottom of the toilet tank to ensure they are tight.
If the toilet does not activate, the gap between the trip
lever and piston actuation arm may need to be reset.
Make sure the trip lever handle is installed, and the trip
lever nut is tight. This is a left-hand thread; turn it
counterclockwise to tighten.
Make sure the water supply is on, and the supply line
water has stopped flowing into the toilet.
Turn the piston nut until there is a 1/32" to 1/16" gap
between the trip lever and the piston actuation arm. Turn
the piston nut clockwise to reduce the gap.
NOTE: Loss of gap clearance adjustment could cause
leakage into the toilet bowl due to the piston not sealing
properly. This condition could cause a continuous flow of
water. If the problem is not corrected after adjustment,
refer to the troubleshooting chart.
B. ADDITIONAL SERVICE INFORMATION
If you would like further service information, you may
order the service manual for this toilet from your dealer.
If you do not want the service manual and the previous
chart has not solved the problem, please refer to your
installer or plumber.
Kohler Co., Kohler WI
Piston Nut
(Turn clockwise to reduce gap,
counterclockwise to increase gap)
Piston Actuation Arm
Gap Adjustment
Trip Lever
(Approximately 1/16")
9
Piston Assembly
Gap Clearance
FA
113362-5-
(9532)