D. Junction Box Installation
If the box is being wired from the OUTSIDE of
the appliance:
• Remove the cover plate located on the outer
shell - right side (see Figure 10.3).
• Install the supplied Romex™ connector in the
cover plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and
reattach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell
(see Figure 10.3).
• Pull the electrical wires from outside the
appliance through this opening into the valve
compartment.
E. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mount-
ed switch for use with a fan (See Fig-
ure 10.4):
• The power supply for the appliance must
be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using a
minimum of 14-3 with ground wire.
• At the switch box connect the black (hot)
wire and red (switch leg) wire to the wall
switch as shown.
• At the appliance connect the black (hot),
white (neutral) and green (ground) wires
to the junction box as shown.
• Add a 1/4 inch insulated female connector
to the red (switch leg) wire, route it through
the knockout in the face of the junction
box, and connect to the top fan switch
connector (1/4 inch male) as shown.
42
Figure 10.3 Junction Box Detail
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections to the junction box/receptacle
and reassemble the junction box/receptacle to the outer shell.
JUNCTION BOX
Figure 10.4 Junction Box Wired to Wall Switch
Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08
GRN wire
inside box
MINIMUM 14-3 AWG
WITH GROUND
Red
Black
White
Green
Red
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
to GRN screw with
GRN wire
NOTE: Do NOT wire
110VAC to wall switch.
SWITCH
Black
White
Green
POWER
SUPPLY WIRES
SWITCH BOX