Graco GH 311797J Repair Manual page 19

Hydraulic sprayers 3300 psi (2.8 mpa, 228 bar) maximum working pressure
Table of Contents

Advertisement

CAUTION
Support pump with your hand before opening t-handle.
8
(Fig. 18) Open clamp (247).
F
. 17
IG
9
(Fig. 19) Remove pump (111) from unit.
F
. 18
IG
311797J
ti8833a
111
ti8832a
Installation
1
(Fig. 20) If needed, place pump rod in adjustment casting
and pull pump to lengthen rod.
ti8834a
F
. 19
IG
2
(Fig. 21) Install pump (111) in sprayer.
F
. 20
IG
3
(Fig. 22) Close clamp (247) around pump (111) and push
it closed.
Adjustment hole
F
. 21
IG
NOTE: Closing force on T-handle can be adjusted if needed by
inserting pin into adjustment hole and turning.
Displacement Pump ProConnect
111
ti8959a
ti8958a
247
19