Ventilate The Spray Booth; Connect The Air Line; Connect The Fluid Line - Graco 218-026 Instructions-Parts List Manual

Manual mid–range electrostatic air spray gun e series
Table of Contents

Advertisement

Ventilate the Spray Booth

WARNING
To prevent hazardous concentrations of toxic
and/or flammable vapors, spray only in a properly
ventilated spray booth. Never operate the spray
gun unless ventilation fans are operating.
Check and follow all of the National, State and
Local codes regarding air exhaust velocity
requirements.
Check and follow all local safety and fire codes and
OSHA standard 1910–107(b)(5)(i).
NOTE: High velocity air exhaust will decrease the oper-
ating efficiency of the electrostatic system. Air
exhaust velocity of 100–150 ft/min (31–46 linear
meters/minute) should be sufficient.

Connect the Air Line

Installation Drawing)
WARNING
To reduce the risk of electric shock or other serious
bodily injury, the air supply hose must be electri-
cally connected to a true earth ground. Use Only
Graco Electrically Conductive Air Supply
Hose. This hose, and the gun, have special
threads which prevent using any other type of
hose with the gun. See the ACCESSORIES sec-
tion to order the hose.
1. Connect the air supply hose (R) between the air sup-
ply line and the gun's air inlet (W). The gun air inlet
fitting has a left hand thread. Connect the air supply
hose ground wire (Q) to a true earth ground.
2. Install an air line filter (O) and an air and water sepa-
rator (D) on the air line to ensure a dry, clean air sup-
ply to the gun. Dirt and moisture can ruin the appear-
ance of your finished workpiece and can cause the
gun to malfunction.
3. Install a bleed–type air regulator (G) on the pump and
gun air supply lines to control air pressure to the
pump and gun.
INSTALLATION
(Refer to the Typical
4. Install a bleed–type air shutoff valve (C, E, P) on the
main air line, the pump line, and each gun air supply
line to shut off air to the pump and/or gun(s). Install
an additional bleed–type valve on each pump air
supply line to relieve air trapped between this valve
and the pump after the air regulator is shut off.
WARNING
The bleed–type air shutoff valve is required in your
system to relieve air trapped between this valve
and the pump after the air regulator is closed.
Trapped air can cause the pump to cycle unex-
pectedly, which could result in serious bodily in-
jury, including splashing in the eyes or on the skin
and injury from moving parts.
5. Install an air line lubricator (F) as close to the pump
(H) as possible.

Connect the Fluid Line

Installation Drawing)
1. Before connecting the fluid line (N), blow it out with air
and flush it with solvent. Use solvent which is com-
patible with the fluid to be sprayed.
2. Install a fluid regulator (M) on the fluid line to control
fluid pressure to the gun.
3. Install a fluid filter (K) and drain valve (V) at the pump
outlet.
WARNING
The fluid drain valve (V) is required in your system
to assist in relieving fluid pressure in the displace-
ment pump, hose and gun; triggering the gun to
relieve pressure may not be sufficient. Install a
drain valve close to the pump's fluid oulet. The
drain valve reduces the risk of property damage or
serious bodily injury, including splashing in the
eyes or on the skin and contamination from haz-
ardous fluids.
4. Connect the fluid line to the 3/8–18.6(m) gun fluid in-
let (X).