Flush the Spray Gun

WARNING
To reduce the risk of fire or explosion and serious
bodily injury, the ES ON–OFF lever must be OFF
before flushing.
1. Follow the Pressure Relief Procedure Warning on
page 9.
2. Disconnect and plug the fluid line.
3. Connect the solvent supply to the gun.
MAINTENANCE
4. Flush the gun with solvent until it is clean.
5. Follow the Pressure Relief Procedure Warning,
then disconnect the solvent supply.
6. Reconnect the fluid supply line.
7. Turn on the fluid and air supplies.
8. Trigger the gun until it is clear of solvent.