B
C
D
Power Supply Must Be Interlocked
With Spray Booth Exhaust Fan.
KEY
A
Main Air Supply Line
B
Ventilation Fan Interlock Solenoid Valve
C
Main Air Supply Shutoff Valve (bleed–type)
D
Air & Water Separator
E
Pump Air Supply Shutoff Valve (bleed–type)
F
Air Line Lubricator
G
Air Pressure Regulator
H
Pump
The Typical Installation shown above is only a guide for
selecting and installing electrostatic air spray systems. It
is not an actual system design. The particular type and
size system for your operation must be custom designed
for your needs. For assistance in designing a system,
contact your Graco representative.

Warning Signs

Mount warning signs in the spray area where they can
easily be seen and read by all operators. See the
ACCESSORIES section to order.

TYPICAL INSTALLATION

A
O
E
H
G
J
F
V
NON–HAZARDOUS AREA
J
K
L
M
N
O
P
M
N
G
P
K
L
U
HAZARDOUS AREA
Pump Ground Wire
Fluid Filter
Fluid Supply Line Shutoff Valve
Fluid Pressure Regulator
Fluid Supply Line
Air Filter (5 micron)
Air Supply Line
Shutoff Valve (bleed–type)
Installing and servicing this equipment requires ac-
cess to parts which may cause electric shock or other
serious bodily injury if work is not performed properly.
Do not install or service this equipment unless
you are trained and qualified.
Be sure your installation complies with National,
State and Local codes for the installation of electrical
apparatus in a Class 1, Group D, Divisions 1 and 2
Hazardous Location.
T
S
W
R
Q
WARNING
SIGN
Q
Spray Gun Ground Wire
R
Grounded Air Supply Hose
S
Electrostatic Spray Gun
T
ES On–Off Valve Lever
U
Air Line Drain Valve
V
Fluid Drain Valve
W
Gun Air Inlet
X
Gun Fluid Inlet
WARNING
X

Advertisement

Table of Contents
loading

This manual is also suitable for: