Normal (Tl) - Vista Quantum Plus Installation And User Manual

H.264 including fsk telemetry
Table of Contents

Advertisement

Quantum Plus installation and user manual
Post Alarm Duration
This is the time for which the DVR will carry on recording, in it's a alarm mode, after an alarm
event has finished. It can be set up to 99 Seconds
Pre-Alarm Resolution
This is the resolution that the DVR will record its Pre- Alarm events in; it can be set to CIF, 2
CIF or D1.
Pre-Alarm FPS
This is the number of pictures per second recorded per camera during the Pre Alarm period.
The maximum FPS will vary dependant on the Pre-Alarm Resolution setting.
Pre-Alarm Duration
This is the time for which the DVR will buffer recordings, to use as pre-alarm events, It can
be set to 0, 5, 10, 15 or 20 seconds

2-2. Normal (TL)

This configures the continuous recording settings per channel
Record rates available:
In CIF (360x288), 25 fps is available to each channel (total 400fps).
In 2CIF (720x288), 12.5 fps is available to each channel (Total 200fps).
In D1 (720x576), 6.25 fps is available to each channel (Total 100fps).
Each channel can be individually configured for record rate and Audio on/off.