Replace Pilot Valves - Graco 24F150 Instruction & Parts Manual

Merkur es spray packages 100 psi (0.7 mpa, 7.0 bar) maximum air inlet pressure a series
Hide thumbs Also See for 24F150:
Table of Contents

Advertisement

Repair
Reassemble the Air Valve
1. See F
. 9. Lubricate detent cam (304◆) and install
IG
into housing.
2. See F
. 10. Lubricate the u-cups (308†◆) and
IG
install on the piston (302◆) with lips facing toward
the center of the piston.
†◆308
Lips face down
◆302
†◆308
Lips face up
F
. 10. Air Valve U-cup Installation
IG
3. See F
. 9. Lubricate both ends of the piston (302◆)
IG
and install it in the housing.
4. Lubricate and install the detent assembly (303◆)
into the piston.
5. Lubricate new o-rings (306†✠◆) and install on the
end caps (307✠). Install the end caps into the hous-
ing.
6. Install a snap ring (310◆✠) on each end to hold end
caps in place.
20
7. Install the spring (311◆). Lubricate and install the
air valve cup (312◆), see F
round magnet with the air inlet.
8. Install the valve plate (305◆). Tighten the screws
(309†◆) to hold it in place.
312◆
F
. 11. Air Valve Cup Installation
IG

Replace Pilot Valves

ti12754a
1. Stop the pump. Follow Pressure Relief Procedure,
page 10.
2. Disconnect the air line to the motor.
3. See F
hold to access the pilot valve on the bottom cover.
4. See F
remove the old pilot valves (213) from the top and
bottom covers.
5. Lubricate and install the new pilot valves (213).
Torque to 95-105 in-lb (11-12 N•m).
. 11. Align the small
IG
Magnet
. 12. Push the safety spring (9) down and
IG
. 14 on page 23. Use a 10 mm wrench to
IG
ti16283a
3A0732B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents