Fault_Act - Planet MGSW-24160F User Manual

16-port 100/1000base-x sfp + 8-port 10/100/1000base-t l2/l4 managed metro ethernet switch
Hide thumbs Also See for MGSW-24160F:
Table of Contents

Advertisement

<dc1>: DC power 1
<dc2>: DC power 2
<ac>: AC power
(default: Set or show digital output/fault alarm 1/2 power_fail)
<enable>: Enable digital input1/2 function
<disable> : Disable digital input1/2 function
(default: Set or show digital input/output/fault alarm 1/2 status)
Example:
Enable power alarm configuration.
SWITCH/>dido do_pwr_alr first dc1 enable
SWITCH/>dido do_pwr_alr first dc2 enable
SWITCH/>dido do_pwr_alr first ac enable

fault_act

Description:
Set or show the system fault alarm action.
Syntax:
dido fault_act [port|power] [enable|disable]
Parameters:
<port >: port fail
<power>: power fail
(default: Set or show digital output/fault alarm 1/2 action)
<enable>: Enable digital input1/2 function
<disable> : Disable digital input1/2 function
(default: Set or show digital input/output/fault alarm 1/2 status)
Example:
Enable power alarm configuration.
SWITCH/>dido fault_act port enable
SWITCH/>dido fault_act power enable
496
User's Manual of MGSW-24160F

Hide quick links:

Advertisement

Table of Contents
loading