Setting Calibration Details [Setting]; Setting The Mode To Execute Selfcalibration [Mode Selection]; Setting The Calibration Targets - Eizo COLOREDGE CG245W User Manual

Calibration color lcd monitor
Hide thumbs Also See for COLOREDGE CG245W:
Table of Contents

Advertisement

4-3. Setting Calibration Details [Setting]

Setting the mode to execute SelfCalibration [Mode Selection]

Set the mode to execute SelfCalibration.
Procedure
1. Choose <Setting> from the SelfCalibration menu, and press
2. Choose <Mode Selection> from the Setting menu, and press
3. Select the mode to change with
4. Select "On" or "Off" with
5. Press
NOTE
"
• When
CAL1/CAL2/CAL3
"
• When
Other Modes
mode will be adjusted as follows:
- In any mode other than CAL mode, the temperature is adjusted so that it is as close as possible to the specified
value.
- In Adobe RGB/sRGB/EBU/REC709/SMPTE-C/DCI modes, the gamut values are adjusted so that they are close
to each specified value.

Setting the calibration targets

Set the calibration targets for SelfCalibration.
Procedure
1. Choose <Setting> from the SelfCalibration menu, and press
2. Choose <Target> from the Setting menu, and press
3. Select the items to change with
The target setting menu is displayed.
4. Select the items to change with
Setting Item
Brightness
White Point
Color Gamut
Gamma
*1
When the color coordinates are set, the temperature changes to [User].
When the temperature is set, the x and y coordinates of the white point are set automatically.
*2
These become [Fixed] when calibrating with ColorNavigator.
*3
5. Adjust using
6. Press
The calibration targets are set.
Attention
• Only set the color gamut calibration when the target color range is precisely known.
• If ColorNavigator was used to calibrate the grey balance, do not change the gamma setting values.
NOTE
• The calibration targets set using ColorNavigator are set as the calibration targets for the monitor.
or
to exit the adjustment.
"
"
is set to
On
"
"
"
is set to
On
, the monitor color reproduction area is updated and the display in each color
Setting Range
30 - 250 cd/m2
Color
: 0.2400 - 0.4500
coordinates
Temperature : 4000 - 10000K (100K Unit)
Native/User
0.0000 - 1.0000
(For each of Red/Green/Blue)
1.6 - 2.7 (0.1 Unit)
*3
or
.
to exit the adjustment.
or
, and press
.
.
"
, SelfCalibration can be executed.
.
or
, and press
.
or
, and press
.
*1
*2
.
.
.
Setting
Set the brightness of the monitor using
the brightness value (cd/m2).
Set the monitor White Point using the
color coordinate or Temperature.
Set whether to calibrate color gamut.
Native : Color gamut calibration is
not performed.
User
: Color gamut calibration is
performed.
To calibrate the monitor color
reproduction gamut, set the color
coordinates for red, green, and blue.
Set the monitor gamma values.
Chapter 4 SelfCalibration
33

Advertisement

Table of Contents
loading

Table of Contents