Troubleshooting; Sit- Nova 820 Gas Control Valve; Sit- Ipi Electronic Gas Control Valve - Montigo L38DF Installation & Maintenance Manual

L-series residential fireplace
Table of Contents

Advertisement

Troubleshooting SIT Nova 820
The following is a troubleshooting chart of possible problems:
PROBLEM
Noisy Pilot Flame
Pilot won't ignite
Main burner will not ignite
All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer.
XG0180 - 053111.1
Maintenance
SOLUTIOn
Locate pilot adjustment screw on gas
control valve. Flame is decreased by
turning adjustment screw clockwise.
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram figure 27.
1. Check wiring (see figure 27).
2. Check wall switch for proper
connection.
If your fireplace still does not operate correctly, consult your local Montigo dealer.
All service and repairs should be performed by a qualified Technician.
Troubleshooting SIT Proflame
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTIOn
Pilot won't ignite or spark.
- Check the on the batteries on the
remote or the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under
the valve
Main Burner Will not light
- Check the wiring diagram on the valve
as per diagram seen in Figure 18.
Fan not working
- Make sure the fan speed control is on.
- 10 minute delay to turn on.
L38DF* Indoor Gas Fireplace
Page 27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L38df indoor l-seriesL38dfnL38dfn-fL38dflL38dfl-f

Table of Contents