MAINTENANCE INSTRUCTIONS

Accidental Starts can cause severe injury or
death.
Disconnect and ground spark plug lead(s)
before servicing.
Normal maintenance, replacement or repair of emission control devices and systems may be performed by any repair
establishment or individual; however, warranty repairs must be performed by a Kohler authorized dealer.

MAINTENANCE SCHEDULE

Every 25 Hours¹
● Service/replace precleaner.
● Replace air cleaner element (if not equipped with precleaner).
Every 100 Hours¹
● Replace air cleaner element (if equipped with precleaner).
● Change oil and filter.
● Remove cooling shrouds and clean cooling areas.
Every 100 Hours
● Check that all fasteners are in place and components are properly secured.
● Replace fuel filter.
Every 200 Hours²
● Have valve lash checked/adjusted.
Every 500 Hours
● Replace spark plugs and set gap.
¹ Perform these procedures more frequently under severe, dusty, dirty conditions.
² Have a Kohler authorized dealer perform this service.
REPAIRS/SERVICE PARTS
Kohler genuine service parts can be purchased from Kohler authorized dealers. To find a local Kohler authorized
dealer visit KohlerEngines.com or call 1-800-544-2444 (U.S. and Canada).
32 690 01 Rev. D
WARNING
KohlerEngines.com
Before working on engine or equipment, disable engine as
follows: 1) Disconnect spark plug lead(s). 2) Disconnect
negative (–) battery cable from battery.
Maintenance
Air Cleaner/Intake
Air Cleaner/Intake
Air Cleaner/Intake
Lubrication System
Air Cleaner/Intake
Reassembly
Reassembly
Electrical System
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents