Installation

Installation instructions

Installation
There should be a minimum
2mm gap between the top of
the dishwasher and
underside of bench top
Inlet water supply
• Cold water pressure: 800 kPa max - 50
kPa min
• Water flow rate 10 L/minute min.
• If cold water pressure is in excess of
800 kPa, a pressure-reducing valve
should be used. Check for leaks.
WARNING!
Make sure that mains plug is disconnected from the mains socket during installation.
Install the appliance under a counter (kitchen worktop or sink).
If a repair is necessary, the appliance must be easily accessible for the engineer.
Put the appliance adjacent to a water tap and drain.
For the venting of the appliance only water hoses and mains cable openings are necessary.
The appliance has adjustable feet to allow the adjustment of its height.
Make sure that the water inlet hose, the drain hose and the mains cable are not kinked or
squashed, when you insert the appliance.
The hose s hould not be
extended by more than
2 metres or water pump-
out problems ma y occu r
Secure dishwasher with
brackets and screws provided
Gap on both sides should be
equal, & no greater than
5mm per side.
K ickplate fixing screws
If floor is not level, adjust
levellin g legs to suit
Remove entire plastic
Fix drain hose max of
membrane from sink trap
10mm below the top of
spigot & fit drain hose to spigot
the dishwashe r
with clamp
600mm max.
300mm min.
POWE R S UPPL Y
230/240V - 1 0 Amps