18 Series Installation - Separate Units
Valve Cartridge Installation
2
A.
2
1
Turn off water supplies. Remove
cover (1), bonnet nut (2) and test cap (3)
from the body. If this is not a thin wall
mounting, the entire plasterguard (4) may
be removed. If screen (5) is in place, remove
before installing cartridge.
C.
2
5
Rotate cartridge (1) so the words
"HOT SIDE" (2) appear on the left. Insert
cartridge assembly into valve body. Make
sure the key (3) on the cartridge is fully
engaged with the slot in the brass body (4).
Slide bonnet nut (5) over the cartridge and
thread onto the body. Hand tighten securely.
4
5
3
1
4
3
B.
3
Insert adapter assembly (1) into valve body.
Make sure the adapter assembly is correctly
positioned and is pressed all the way down
inside body. Secure adapter with the screw
(2) provided in the adapter assembly.
Remove the retainer (3) from the adapter.
Back to back Installation
Normal Installation
(changes not required)
Reverse
Installation
3
1
For back to back or reverse installations
(hot on right and cold on left): Rotate cartridge
(1) so the words "HOT SIDE" (2) appear on the
right. Install the cartridge making sure that the
key is fully engaged with the slot in the brass
body (See step C). Slide bonnet nut (3) over
the cartridge and thread onto the body. Hand
tighten securely.
6
1
2
2
Cold
Hot