Specifications; Fuel Requirements; Engine Oil Requirements; Generator Specifications - Generac Power Systems 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 Owner's Manual

Air-cooled recreational vehicle generators
Hide thumbs Also See for 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0:
Table of Contents

Advertisement

Figure 1.1 – Connection for 120 Volts Only
Figure 1.2 - Connection for 120/240 Volts
GROUNDED NEUTRAL
STATOR WINDINGS
1.6

SPECIFICATIONS

1.6.1 FUEL REQUIREMENTS (GASOLINE)
This generator is equipped with a gasoline fuel system
as standard equipment. Specific installations may pro-
vide either a separate fuel tank for the generator, or the
generator may "share" the vehicle engine's fuel tank.
SERIES
Rotor RPM
Rotor Poles
Engine RPM
Rated Max. Continuous AC Output Watts*
Voltage*
Rated Max. Continuous Current Amps (240V)
Phase
Frequency
Battery Charging Current (Max.)
Weight
Length
Width
Height
* All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output
6
Generac
®
Power Systems, Inc.
Section 1 – General Information
QUIETPACT 55, 65, and 75 Recreational Vehicle Generators
T1
RED
CB1
T2
WHITE
CB2
T3
BLACK
1.6.3
QP55G
3600
2
2200
5500
120
45.8 (22.9)
1
60 Hertz
2 amps
326 lbs.
33.7 in.
22.2 in.
19.6 in.
1.6.1.1 Fuel Consumption (gph/lbs.ph)
Model
QuietPact 55G
QuietPact 65G
QuietPact 75G
Some installations using a "shared" fuel tank may
have a generator fuel pickup tube that is shorter
than the vehicle engine's pickup tube. Such an
arrangement causes the generator engine to "run
out of gas" while adequate fuel for the vehicle
remains in the tank.
To reduce lead and carbon deposits use high quality
UNLEADED gasoline with the generator. Leaded
REGULAR grade gasoline is an acceptable substitute.
Using unleaded gasoline contributes to longer engine
valve life by reducing lead and carbon deposits.
Generac does not recommend using any
!
gasoline containing alcohol (such as "gasohol").
If you use any gasoline containing alcohol, it
must not contain more than 10 percent ethanol,
and it must be removed from the generator
during storage. Do NOT use any gasoline
containing methanol. If you use gasoline with
alcohol, inspect more frequently for fuel leaks
and other abnormalities.

1.6.2 ENGINE OIL REQUIREMENTS

Use only high quality detergent oil classified "For
Service SF" and with an oil viscosity rating of SAE
10W-30 oil. Do not pour in any additives to the rec-
ommended oil. Engine crankcase capacity is 1.8
liters or 1.9 quarts with oil filter change. See Section
3.2 on page 11 for oil level check and filing proce-
dures.

GENERATOR SPECIFICATIONS

QP55LP
QP65G
3600
3600
2
2
2200
2571
5500
6500
120
120
45.8 (22.9)
54.1 (27.0)
1
1
60 Hertz
60 Hertz
2 amps
2 amps
329 lbs.
328 lbs.
33.7 in.
33.7 in.
22.2 in.
22.2 in.
19.6 in.
19.6 in.
10% Load
50% Load
0.51
0.73
0.51
0.76
0.51
0.80
NOTE
NOTE:
QP65LP
QP75G
3600
3600
2
2
2571
2571
6500
7500
120
120
54.1 (27.0)
62.5 (31.2)
1
1
60 Hertz
60 Hertz
2 amps
2 amps
331 lbs.
330 lbs.
33.7 in.
33.7 in.
22.2 in.
22.2 in.
19.6 in.
19.6 in.
100% Load
0.97
1.07
1.28
QP75LP
3600
2
2571
7500
120
62.5 (31.2)
1
60 Hertz
2 amps
333 lbs.
33.7 in.
22.2 in.
19.6 in.

Hide quick links:

Advertisement

Table of Contents
loading