Connecting To The Mains Terminal; Connecting To A Hob Or Cooker Point; Checking Electrical Connections - Electrolux EOD6335 Manual

Hide thumbs Also See for EOD6335:
Table of Contents

Advertisement

CONNECTING TO THE MAINS TERMINAL

Warning: This appliance must be earthed.
·
Make connection as shown in Fig. 6 by
proceeding as follows:-
Fig.6
·
Preform wires to the appropriate shape to suit
fitting into the mains terminal block.
·
Strip
inner
insulation
wirestrippers.
·
Twist the bared wires using pliers.
·
Cut bared wires 10mm away from the end of the
inner insulation. Where uninsulated Earth wires
are used ensure they are suitably sheathed to
leave 10mm bare wire to fit into the terminal.
·
Clamp bare wires into the relevant terminal and
check they are held by tugging each one in turn.
·
Clamp the mains cable securely ensuring 5mm of
the outer insulation is inside the terminal block
and that the wires are not taught but not so slack
as to cause any fouling. See Fig. 6.
·
Place fuse/miniature circuit breaker in circuit and
switch on at mains.

CONNECTING TO A HOB OR COOKER POINT

WARNING:
THIS
APPLIANCE
EARTHED
·
Either follow in general terms the instructions for
connecting to the terminal block or refer to the
hob suppliers installation instructions.
Feed the cable through the cabinet and
arrange to route the cable away from the
appliance which may become hot.
on
wires
using
MUST
BE
10

CHECKING ELECTRICAL CONNECTIONS

·
Confirm the appliance is correctly connected by
switching on and observing the various oven
functions indicators.
·
The electronic timer will flash on and off.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried
out before the appliance is connected to the mains
supply and re-checked after fitting.

Advertisement

Table of Contents
loading

Table of Contents