Chauvet SlimPAR User Manual
Hide thumbs Also See for SlimPAR:

Advertisement

Quick Links

User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet SlimPAR

  • Page 1 User Manual...
  • Page 2: Table Of Contents

    Infrared Remote Control .......................... 14 IRC Operation ............................15 Master/Slave Mode ..........................16 5. Technical Information ....................17 Product Maintenance ........................17 6. Technical Specifications ....................18 Returns ............................19 Contact Us ............................19 Page 2 of 19 SlimPAR™ HEX 3 IRC User Manual Rev. 2...
  • Page 3: Before You Begin

    Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection. For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with CHAUVET® within 7 days of delivery. Text Convention Meaning 1—512...
  • Page 4: Product At A Glance

    This product is not intended for permanent installation. · Keep this User Manual for future use. If you sell the product to another user, be sure to give this document to the next owner. Page 4 of 19 SlimPAR™ HEX 3 IRC User Manual Rev. 2...
  • Page 5: Introduction

    2. I NTRODUCTION Overview Power In Safety Loop DMX In Fuse Holder Microphone Control Buttons Display Power Out DMX Out Back Panel View SlimPAR™ HEX 3 IRC User Manual Rev. 2 Page 5 of 19...
  • Page 6: Dimensions

    Dimensions 7.4 in 187 mm 8.3 in 210 mm 4.3 in 108 mm Page 6 of 19 SlimPAR™ HEX 3 IRC User Manual Rev. 2...
  • Page 7: Setup

    ETUP AC Power The SlimPAR™ HEX 3 IRC has an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or...
  • Page 8: Power Linking

    Diagram Additional Products You can power link up to 21 SlimPAR™ HEX 3 IRC units on 120 VAC or up to 39 SlimPAR™ HEX 3 IRC units on 230 VAC. The power linking diagram shown above corresponds to the North American version of the product ONLY! If using the product in other markets, you must consult with the local CHAUVET®...
  • Page 9: Mounting

    Mounting Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation The SlimPAR™ HEX 3 IRC may be mounted in any position; however, make sure adequate ventilation is provided around the product. · Rigging Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.
  • Page 10: Operation

    W 0—W255 White (0—100%) P 0—P255 Ultraviolet (0—100%) Dimmer, off dIM1 Dimmer, fast speed Dimmer Mode dIM2 Dimmer, medium speed dIM3 Dimmer, slow speed Infrared Turns infrared on or off Page 10 of 19 SlimPAR™ HEX 3 IRC User Manual Rev. 2...
  • Page 11: Configuration (Dmx)

    DMX mode uses. If you choose a starting address that is too high, you could restrict the access to some of the product’s channels. The SlimPAR™ HEX 3 IRC uses up to 12 DMX channels in its 12-channel DMX mode, which defines the highest configurable address to 501.
  • Page 12: Dmx Channel Modes, Assignments, And Values

    000 ó 255 0 to 100% Blue 000 ó 255 0 to 100% Amber 000 ó 255 0 to 100% White 000 ó 255 0 to 100% Ultraviolet Page 12 of 19 SlimPAR™ HEX 3 IRC User Manual Rev. 2...
  • Page 13: Configuration (Standalone)

    To set the auto program speed, follow the instructions below: Press <MENU> repeatedly until S-- shows on the display. Use <UP> or <DOWN> to select the desired auto program speed S 1–S100 (slow to fast). Press <ENTER>. SlimPAR™ HEX 3 IRC User Manual Rev. 2 Page 13 of 19...
  • Page 14: Static Colors

    Use <UP> or <DOWN> to select the desired dimmer mode. Press <ENTER>. Infrared Remote The SlimPAR™ HEX 3 IRC is fully compatible with the Infrared Remote Control (IRC) from CHAUVET®. To enable use with the IRC, follow the instructions below: Control Press <MENU>...
  • Page 15: Irc Operation

    Note: The IRC will not respond to any inputs when Black Out is activated. If the remote does not respond when a button is pressed, try pressing <BLACK OUT>. You may have inadvertently activated Black Out. SlimPAR™ HEX 3 IRC User Manual Rev. 2 Page 15 of 19...
  • Page 16: Master/Slave Mode

    Master/Slave The Master/Slave mode allows a single SlimPAR™ HEX 3 IRC unit (the “master”) to control the actions of one or more SlimPAR™ HEX 3 IRC units (the “slaves”) without the Mode need of a DMX controller. The master unit will be set to operate in either Automatic or Sound-Active mode, while the slave units will be set to operate in Slave mode.
  • Page 17: Technical Information

    Gently polish the external optics and glass/transparent surfaces until they are free of haze and lint. Always dry the external optics and glass/transparent surfaces carefully after cleaning them. SlimPAR™ HEX 3 IRC User Manual Rev. 2 Page 17 of 19...
  • Page 18: Technical Specifications

    104 °F (40 °C) Convection I/O Connectors Connector Type Channel Range 3-pin XLR Sockets 6, 8, 12 Ordering Product Name Item Code UPC Number SlimPAR™ HEX 3 IRC 03030737 781462210854 Page 18 of 19 SlimPAR™ HEX 3 IRC User Manual Rev. 2...
  • Page 19: Returns

    You must send the merchandise prepaid, in its original box, and with its original packing and accessories. CHAUVET® will not issue call tags. Clearly label the package with the RMA number. CHAUVET® will refuse any product returned without an RMA number.

This manual is also suitable for:

Slimpar hex 3 irc

Table of Contents