Desa UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE Owner's Operating & Installation Manual page 25

Unvented (vent-free) propane/lp gas fireplace, variable manually controlled models and thermostatically controlled “b” models with split oak logs
Table of Contents

Advertisement

OPERATING
FIREPLACE
Manually-Controlled
Models
Continued
103415
6. Continue pressing control knob in. Press and release ignitor button. This will light
pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button
until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service person or gas supplier for
repairs. Until repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure, below.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
Thermocouple
8. Slightly depress and turn control knob counterclockwise
position. Both burners should light. Set control knob to either HIGH or LOW.
VARIABLE CONTROL OPERATION
The variable control valve can be set to any heat setting and flame height desired, by
simply turning the control knob until that setting is attained. Even the lowest setting
provides realistic flames and glowing embers from two burners. Selecting higher settings
produces greater heat output. This results in increased heating comfort.
Do not operate heater between locked positions.
Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
2. Slightly depress control knob and turn clockwise
3. Slightly depress control knob and turn clockwise
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise
2. Press in and turn clockwise
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 24.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8, above.
Pilot Burner
Ignitor Electrode
Figure 32 - Pilot
WARNING
WARNING ICON
G 001
CAUTION
WARNING ICON
G 001
to the HIGH position.
Clockwise
Clockwise
Clockwise
to the HIGH position.
Clockwise
to the PILOT position.
Clockwise
to the HIGH
C-clockwise
to the PILOT position.