C-View Residential R520-R620 Series Indoor Gas Fireplace
Step 5.
Securely fasten the bottom Collar pan into the Rough-in frame
using the existing hardware, (4-pcs). Tighten the Strain Relief nut
onto Strain relief fitting.
Step 6.
Pull the Power Vent Connector, (from behind) half-way through
supplied hole in conduit mounting frame, and snap into place,
(notches in two plastic wing clips. Orientation not critical).
Figure 5d. (Installing Conduit connector & conduit mounting frame)
Step 7.
Fasten the Conduit mounting frame into place using the existing
hardware, (6-pcs). (Coil conduit in behind cover.)
Figure 5e. (Assembled Rough-in Kit)
Step 8.
Install the Power Vent Power / communication harness. Hold the
Power Vent in close proximity of the assembled Rough-in Kit,
and plug in the Power Vent communication / Power Cord. (Note
the direction and orientation of the pins inside the Power Vent
connector, the snap them together). (Figure 5f).
Page 12
Installation
Strain Relief & tightened nut
Power Vent Conduit
Conduit
mounting
frame
Power Vent
Connector
Tightened hardware,
4-pcs.
Installed Power
Vent Connector
Tightened hardware,
6-pcs.
Figure 5f. (Installation of Power Vent communication harness)
Step 9.
Install the Power Vent. Place the Power Vent into the Rough-in
frame, aligning the Power Vent into final position. Ensure the
Harness is placed down in the Rough-in box when placing the
Power Vent. (Secure the Power Vent in Place with the supplied
hardware).
Tightened hard-
ware,
4-pcs.
Figure 5g. (Completed Installation of Power Vent)
f i r e f e a t u r e
Communication
Harness.
TOP of Power Vent,
(Note Quantity of
louvers).
Note louver
direction
Part No. XG0771 - 0070111

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

R620