Step 4. Enable/Disable Alarm
This machine features a buzzer alarm that will sound to notify the operator when one of the following
three things has occurred:
• BIB Tracking has detected an empty BIB (See step 4)
• A machine malfunction has been detected
• The machine has completed a sanitization cycle
This feature offers the option to disable the buzzer alarm.
To enable the alarm, use the + or – switch to scroll until the display reads ON.
To disable the alarm use the + or – switch to scroll until the display reads OFF. See figure 7. When
you have made your selection, press "Enter" to save and proceed to the next programming option.
SEL will appear on the display screen. See figure 8.
Fig. 7
Step 5. Program Selector Switches
This machine features a 7-selector switch control panel. The center switch on the control panel is
reserved for Hot Water Dispense. The remaining 6 switches can be programmed to deliver a drink
from either of the product BIBs or can be programmed to create a drink by blending product from both
BIBs.
In order to proceed with switch programming, it is first necessary to familiarize you with pump
orientation.
Pump 1 is mounted on the left side of the mixing chamber. (When facing the machine from the front.)
Pump 1 supports the product BIB that is installed directly above it.
Pump 2 is mounted on the right side of the mixing chamber. Pump 2 supports the product BIB that is
installed directly above it.
To program a selector switch to create a drink using the product on the left, enter the pump speed
from Chart A below in to Pump 1 and set the speed of Pump 2 to :00