KEYPAD CONFIGURATION MODE

Feedback Beep (Default = ON)
Upon entering the Keypad Configuration Mode (press
to exit), "Feedback Beep Presently ON" displays, indicating that the
tactile beep, which sounds when any button is pressed, is on. To turn
off the tactile feedback beep, press
immediately turn off, and the system will advance to the next selection
(Keypad Sounder). If feedback beep is off and you wish to turn it on
again, press
B
(to scroll back). Display will read "Feedback Beep
U
Presently OFF". Press
to turn on.
Keypad Sounder (Default = ON)
To turn off the keypad sounder, press
except for the Feedback Beep. Do not program in U.L. installations.
E/E Countdown (Display) (Default = ON)
Exit delay allows time for the user to leave the premises after arming;
entry delay provides the user time to enter and disarm. To turn off (or
turn on) the display of the exit/entry delay countdown, press
Note: Requires times to be entered. See Exit/Entry Time Display on
next page. Note: Factory program defaults to 30 and 45 seconds for
Entry and Exit delays, respectively.
Display Zn Fault (Default = ON)
To turn off the scrolling display of zone faults, press
zones exist and this setting is OFF, window will only display "Zone
Faulted" and not scroll zones.
Keypad PGM Opt (Default = OFF)
A common use of this feature is to activate a door strike for the
purposes of remotely unlocking a door.
negative output that is activated when this option is selected and by
U
pressing
. If this option is OFF, the Activate Access function will not
display in the Function Menu. Connect the device controlled by the
PGM between +PWR and the PGM terminal (maximum load of 10
mA). The PGM Output will remain ON for approximately 7 seconds.
Dialer Test Opt (Default = OFF)
Testing the dialer is initiated through the Function Menu. Turning ON
the Dialer Test Item enables the Activate Dialer Test entry to be listed
in the Function Menu. If turned OFF, the Activate Dialer Test entry is
removed from the Function Menu. The Dialer Test Option is not sup-
ported with the GEM-P800 and therefore must be turned off here if
used with this panel.
Easy Exit Option (Default = OFF)
This option allows a user to exit the premises while the system is armed. If
OFF, the Easy Exit function will not display in the Function Menu. Turn
OFF if not enabled in Panel. This feature should not be used in U.L. instal-
lations.
Ready Message Option (Default = OFF)
An alternate message can be used in place of the default "SYSTEM
READY" message when keypad is in a normal state. The alternate
message is "READY TO ARM" but can be changed to any other text
message by using the PC Quickloader software.
Keypad Panics F=4 A=2 P=1 (Default = 7)
1=Panic
2=Aux
5=Panic & Fire
6=Aux & Fire
Each Panic Zone is always a 24-Hour Zone, and each keypad can be
individually programmed for keypad panics. Enter the sum of the dis-
played numbers to activate the selected Panic Zone(s) as follows:
If "Keypad Panic" (P) is programmed for a keypad, police panic is
activated by pressing
9
programmed, pressing
8 G
Page 2
C
U
. The tactile feedback beep will
U
. All keypad sounds will be off,
U
. If faulted
The PGM is a switched
3=Panic & Aux
4=Fire
7=Panic, Aux & Fire
0=None
and
G
. If "Keypad Aux." (A) is
will trip an auxiliary emergency
alarm. If "Keypad Fire" (F) is programmed, pressing
will activate fire panic. These features must also be enabled in panel pro-
gramming via Dealer Mode. Press
any time
tions: If Keypad Fire [20-1] is enabled, the keypad must be mounted within
(3) three feet from the Control Panel with no intervening walls or barriers.
Keypad Address (Default = 0)
Each keypad must be assigned a unique keypad address (that is, no
two keypads may be numbered alike) in order for the PCD Windows
Downloader software to correctly configure the keypads. Keypads
must be numbered consecutively, and missing numbers are not
permitted. To assign the keypad number, enter the assigned keypad
number 1–4, then press
EZM Address (Default = 0)
The GEM-RP8LCD keypad includes an internal EZM (Expansion Zone
Module) that may be enabled to provide two additional hard wired
zones, assigned to zones 7 & 8. The system will support up to 2
EZMs, EZM1 and EZM2. If the EZM is not used, the EZM address
must be left at the default of "0". To enable the EZM in the keypad,
enter an EZM address of "1" or "2", and press
U
.
If 2 Keypad EZM zones are required from one keypad, enable EZM1 (1).
If only 1 Keypad EZM zone is required, enable keypad EZM1 (1).
If 1 Keypad EZM zone is required from one keypad and 1 zone from
another, enable EZM1 (1) in one keypad and EZM2 (2) in the other.
EZM Zones Enable (Default = 3)*
* EZM Address must be 1 or 2 for Zones to be enabled.
After the Keypad EZM has been enabled, the Zone(s) to be used on
the Keypad EZM must also be enabled as follows:
To enable EZM zone 1, enter 1 on the display and press
To enable EZM zone 2, enter 2 on the display and press
To enable both EZM zones 1 and 2, enter 3 and press
NOTE: If zones are enabled, then 2.2K EOL resistor (provided)
must be used (in parallel with N/O, in series with N/C devices).
Assigning EZM Zones in Dealer Program Mode
In addition to configuring the keypad, the panel must be programmed
for the use of keypad EZM zones. These zones must be mapped to
zones 7 & 8 in the same fashion as RF transmitters - by entering a
special RF ID and point # in blocks 77 & 78, as follows:
Keypad configured as EZM 1:
To enable Zone 1 on Keypad EZM 1:
1. Enable EZM Address 1 as described above.
2. Enable EZM zone 1 as described above in "EZM Zones Enable".
3. Go to block 77 and enter RF ID# 111111:5-1 (point 1) to map to
zone 7 (or block 78 to map to zone 8).
4. Wire zone device to the keypad Orange and Gray wires.
To enable Zone 2 on Keypad EZM 1:
1. Enable EZM Address 1 as described above.
2. Enable EZM zone 2 as described above in "EZM Zones Enable".
3. Go to block 77 and enter RF ID# 111111:5-2 (point 2) to map to
zone 7 (or block 78 to map to zone 8).
4. Wire zone device to the keypad Blue and Gray wires.
Keypad configured as EZM 2:
To enable Zone 1 on Keypad EZM 2:
1. Enable EZM Address 2 as described above.
2. Enable EZM zone 1 as described above in "EZM Zones Enable".
3. Go to block 77 and enter RF ID# 222222:b-1 (point 1) to map to
zone 7 (or block 78 to map to zone 8).
4. Wire zone device to the keypad Orange and Gray wires.
To enable Zone 2 on Keypad EZM 2:
1. Enable EZM Address 2 as described above.
2. Enable EZM zone 2 as described above in "EZM Zones Enable".
3. Go to block 77 and enter RF ID# 222222:b-2 (point 2) to map to
zone 7 (or block 78 to map to zone 8).
7
U
to save your selection. U.L. Installa-
U
to save.
U
to save.
and
G
U
.
U
.
U
.