F - 6 4 T P T O U C H P AD C O N T R O L S & I N D I C A T O R S
LCD Window – 32 character LCD displays
1
system
status
messages,
descriptions, system troubles, etc.
STATUS Light. Lights (green) to indicate
2
that the system is ready for arming. If a
zone is not secured, the light will be off
and the zone will display in the window. If
a zone has been bypassed, the STATUS
light will blink while armed.
ARMED Light. Lights (red) to indicate that
3
the system is armed. If an alarm has
occurred, the ARMED LED will be
flashing.
4
Alarm Speaker – Will sound a LOUD
steady sweep tone when intrusion is
detected or a distinct pulsating tone for a
fire alarm condition.
indicate armed AWAY, and provides for
audible voice prompts.
5
STAY Button – Press once to initiate the
arm Stay sequence.
bypasses
all
interior
simultaneously to allow free movement
within the premises. Hold down for 2
seconds if all zones secure to eliminate
60-second pre-arm delay.
AWAY Button – Press to initiate arm
6
AWAY sequence when no one is to
remain home. Exit through the door and
engage the deadbolt from outside the
premises. System will be fully armed with
all
zone
activated.
BYPASS Button – Press to enter the
7
Bypass Menu, where system functions
are displayed in the LCD window. Press
YES to select the desired function; press
RESET to exit.
deactivates the zone from the system.
8
MENU Button – Press to enter Function
Mode,
functions are displayed in the LCD
window.
selected by pressing the YES button.
Press RESET to exit.
DISARM / RESET Button – Press to silence
9
Fire alarms, troubles and exits Function
Also chirps to
Mode (see MENU Button).
YES Button – Press to select the desired
10
function in menus (see MENU Button,
above).
Stay Mode
NO Button – Press to answer no to menu
11
zones
questions and proceed to the next
question (see MENU Button, above).
12
ENTER Button – Press to accept displayed
value and to move cursor to next position.
13
Integral PIR – Used to detect intruders and
your presence near the Touchpad during
arming and disarming. Do not block.
14
FIRE Button – Press and hold down for 2
seconds to alert the Central Station of a
fire emergency.
perimeter
and
interior
devices
Bypassing a zone
in
which
available
system
The desired function is then
+
15
AUX Button – Press and hold down for 2
seconds to alert the Central Station of a
auxiliary emergency.
Police Button – Press and hold down for
16
2 seconds to alert the Central Station of a
police emergency.
17
I-FOB – The I-FOB is a uniquely coded
digital key.
Insert the I-FOB into its
keyhole to disarm the system and silence
the siren in case of an alarm.
Slide Plate – Lift to view brief descriptions of
18
Touchpad buttons and procedures.
19
Bypass Icon – Appears as a reminder that
zones have been bypassed (by pressing
the BYPASS button). If it is necessary to
bypass any inoperative zones, it is
important to have the zones repaired as
soon as possible.
Fire Icon – Steady indicates a fire alarm
20
condition. Flashing indicates fire alarm
sounding.
21
Fire TBL Icon – Indicates a problem on a
fire zone is detected.
22
System TBL Icon – Indicates a trouble
condition exists on the system. Press
SILENCE to silence sounder and display
the trouble.