TYAN M3291 Basic Manual
TYAN M3291 Basic Manual

TYAN M3291 Basic Manual

Server management daughter card & tyan system operator
Hide thumbs Also See for M3291:

Advertisement

M3291/3295
Server Management Daughter Card
& Tyan System Operator
Revision V2.00
Copyright © TYAN Computer Corporation, 2006-2007. All rights reserved. No part of
this manual may be reproduced or translated without prior written consent from TYAN
Computer Corp.
All registered and unregistered trademarks and company names contained in this
manual are property of their respective owners including, but not limited to the following:
TYAN is a trademark of TYAN Computer Corporation
Intel is a trademark of Intel Corporation
Renesas is trademark of Renesas Technology Corporation
Windows and HyperTerminal are a trademark of Microsoft Corporation
ARM is a registered trademark of ARM Limited
JDK is copyrighted by Sun Microsystems, Inc.
ACE and TAO are copyrighted by Douglas C. Schmidt
Winpcap is copyrighted by the University of California, Lawrence Berkeley Laboratory
Information contained in this document is furnished by TYAN Computer Corporation
and has been reviewed for accuracy and reliability prior to printing. TYAN assumes no
liability whatsoever, and disclaims any express or implied warranty, relating to sale
and/or use of TYAN products including liability or warranties relating to fitness for a
particular purpose or merchantability. TYAN retains the right to make changes to
product descriptions and/or specifications at any time without notice. In no event will
TYAN be held liable for any direct or indirect, incidental or consequential damage, loss
of use, loss of data or other malady resulting from errors or inaccuracies of information
contained in this document.
1
http://www.tyan.com

Advertisement

Table of Contents
loading

Summary of Contents for TYAN M3291

  • Page 1 Winpcap is copyrighted by the University of California, Lawrence Berkeley Laboratory Information contained in this document is furnished by TYAN Computer Corporation and has been reviewed for accuracy and reliability prior to printing. TYAN assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of TYAN products including liability or warranties relating to fitness for a particular purpose or merchantability.
  • Page 2: Table Of Contents

    Page 6 Features of Tyan Server Management Page 7 How SMDC and TSO work Page 11 Operating System Compatibility Page 11 Chapter 2: M3291 Hardware Information M3291 Card Images Page 12 M3291 Card Layouts Page 12 M3291 Jumper Setting Page 13...
  • Page 3: Box Contents

    M3291 Box Contents The retail M3291 package should contain the following: 1 x TYAN System Management Daughter Card 1x 50-pin Ribbon Cable 1 x Serial-to-Serial Cable 1 x Standard PCI Bracket 1 x Low Profile PCI Bracket 1 x HD Bay Bracket (Option) 1 x SMDC &...
  • Page 4: About This Manual

    About this Manual This manual is designed to provide the basic information for the SMDC M3291/3295. It includes the introduction of hardware, software and general troubleshooting procedures. Chapter 1: Overview – Includes the basic introduction of SMDC, TSO, OPMA and M3295, and Server Management.
  • Page 5: Chapter 1: Overview

    TSO is fully compatible with all major Operating Systems. 1.2 SMDC and TSO The TSO is software made by Tyan which acts as a front end client that provides additional functionality for the SMDC. The SMDC and TSO offer remote management over servers.
  • Page 6: Opma And M3295

    M3295 is OPMA compatible card. It’s also compatible with IPMI 2.0 and has dedicated management NIC support. Dedicated management NIC provides high performance and reliability. M3291 M3295 Interface Tyan 2X25 Connector AMD OPMA Management NIC Side-band(Shared) Dedicated The specification is available for download from AMD website http://www.amd.com/us-en/Processors/ProductInformation/0,,30_118_8796_12498,00.html...
  • Page 7: Features Of Tyan Server Management

    Diagnostic command execution. BMC Firmware SMDC supports onboard update of the BMC firmware. Update Alert Standard Forum Tyan System Operator ™ The SMDC M3291/3295 is equipped with the following features: Hardware Monitoring Protocol and Standard Enhanced Authentication Encryption Support http://www.tyan.com...
  • Page 8 Standard or OEM Drivers Hardware Monitoring The latest hardware from TYAN is equipped with Baseboard Management Controller (BMC) from Renesas H8 which provides not only system monitoring but also remote manageability. The BMC can always monitor the hardware regardless of how the operating system is running.
  • Page 9 Remote Console Redirection allows IT managers to effectively control and maneuver text console of a remote machine. Serial console information goes through the M3291/3295 SMDC and is processed over the network. TSO software then reproduces the exact text console at a remote location. For example, someone may own a group of servers at a remote location and could change options of those servers from a completely separate location.
  • Page 10 SDR is specific to motherboard. Tyan provides a utility to easily upgrade the BMC firmware to support each motherboard model. System Event Log (SEL) A complete history of system events such as POST events are stored and secured in non-volatile memory.
  • Page 11: How Smdc And Tso Work

    RH Linux 7.2, 7.3, 8.0, 9.0 (32/64-bit) Adv. Server 2.1, 3.0, 4.0 (32/64-bit) SuSE® SuSE Enterprise Server 8.0, 9.0 (32/64-bit) Professional 9.0, 9.1, 9.2,9.3,10.1 (32/64-bit) TYAN reserves the right to add support or discontinue support for any OS with or without notice. http://www.tyan.com...
  • Page 12: Chapter 2: M3291 Hardware Information

    Chapter 2: M3291 Hardware Information 2.1 M3291 Card Images 2.2 M3291 Card Layouts http://www.tyan.com...
  • Page 13: M3291 Jumper Setting

    2.3 M3291 Jumper Setting Label Header Type/Part Description Pin Layout HDR25X2_SVM_A SVM Edge Connector A COM Port Signal remapped for Pin 1 M/B COM2 (9Pin Pin 2 GND) Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8...
  • Page 14: M3291 Card Installation

    Unplug the power cord from your computer power supply and then touch a safely grounded object to release static charge (i.e. power supply case). For the safest conditions, TYAN recommends wearing a static safety wrist strap. (2) Hold the SMDC by its edges and do not touch the bottom of the card.
  • Page 15 Step 2: Connect 2x25 ribbon cable between Tyan motherboard SMDC connector and Tyan SMDC J1. Make sure that the key on the ribbon cable aligns with the key on the connector, and that the red line on the ribbon aligns with pin 1 of the connector.
  • Page 16 1 of the connector. Step 4: Locate the onboard “SMDC-Link” Network Interface Controller (NIC) on Tyan motherboard. (M3291 uses one of motherboard onboard NIC for IPMI out-of- band. Before using, please make sure which port M3291 used. You can refer to http://www.tyan.com/support/html/faq_tso.html...
  • Page 17: Chapter 3: M3295 Hardware Information

    Unplug the power cord from your computer power supply and then touch a safely grounded object to release static charge (i.e. power supply case). For the safest conditions, TYAN recommends wearing a static safety wrist strap. (7) Hold M3295 by its edges and do not touch the bottom of the card.
  • Page 18 Step 1: Insert the card with a degree about 45º into the OPMA socket on the motherboard. Step 2: Press down the card into the socket. Step 3: When properly seated, the retention clips lock into position. http://www.tyan.com...
  • Page 19: Chapter4: Software Installation

    Users can refer to http://www.tyan.com/support/html/faq_tso.html SMDC Support List If you wan to know the detail about BIOS for IPMI, please refer the M3291/3295 FAQ. Broadcom NIC Firmware Update It’s M3291 only. M3295 use dedicated NIC. So there’s no such requirement for M3295.
  • Page 20 So before using M3291/3295, User also need update M3291/3295 motherboard specified firmware. M3291/3295 Driver CD contains the firmware file. User also can get the latest firmware from Tyan website. Tyan provide both DOS and Linux utility for firmware updating. The firmware release packages include these two utility already.
  • Page 21: Configuration

    4.2- Configuration Before using M3291/3295, users need do some configuration first, such as IP Address. Otherwise some IPMI function won’t work. Users can use the standard IPMI software to set. And Tyan also provide some utilities to do them. The most important configuration are LAN Configuration and User Password Setting.
  • Page 22 UH8D.EXE M3291/3295 Thin Version Utility on DOS It support do configuration via command line. “uh8d /?” for the detail usage. UH8L M3291/3295 Utility on Linux. It use its own user space driver. So don’t use any other IPMI driver when using this utility “./uh8l –h”...
  • Page 23 Normally user need not set MAC address, but users need check if the MAC address is right. For Intel 82551 and 82546 NIC, M3291 use the same MAC address with system OS. Tyan IPMI enabled BIOS will load it automatically. If not, user...
  • Page 24: Open Sourced Ipmi Software

    Linux and Solaris. Users can use it to view most of IPMI jobs remotely. Detail please refer to ipmitool man page: http://ipmitool.sourceforge.net/manpage.html . IPMITool 1.8.2 have some issue and only partly work on M3291/3295. Please use the latest code from CVS server.
  • Page 25 Power Control http://www.tyan.com...
  • Page 26 Serial Over LAN (SOL) http://www.tyan.com...
  • Page 27: What Is Tso

    Chapter 5: Software Information Tyan System Operator (TSO) is an IPMI-aware management tool for systems based on TYAN motherboards. Through TSO, Users have an easier way to remotely access system health information, do system maintenance and make the running systems much safer.
  • Page 28: Tso Connection Models

    5.2 TSO Connection Models 5.2.1 Simple Intranet Model-1 TSO MANAGER and CONSOLE can be loaded onto the same system TSO AGENT can only work over Tyan server motherboards (Check www.tyan.com TSO FAQ) 5.2.2 Simple Intranet Model-2 TSO MANAGER and CONSOLE can be loaded onto two separate systems...
  • Page 29: Simple Intranet Model-3

    5.2.3 Simple Internet Model-3 TSO MANAGER and CONSOLE can be loaded onto two separate systems TSO AGENT can only work over Tyan server motherboards http://www.tyan.com...
  • Page 30: Complex Intranet Model

    5.2.4 Complex Internet Model TSO MANAGER and CONSOLE can be loaded onto separate systems TSO AGENT can only work over Tyan server motherboards (Check www.tyan.com TSO FAQ) All TSO CONSOLE systems can log in different MANAGER to read/control AGENT systems...
  • Page 31: Tso Access Model

    (1) pass the MANAGER Authentication and (2) pass the AGENT Authentication to access all In-Band features Out-Of-Band Access CONSOLE needs to (1) pass the MANAGER Authentication and (2) pass the SMDC Authentication to access all Out-Of- Band features External-IP and Internal-IP http://www.tyan.com...
  • Page 32: Features

    Servers under monitoring can be grouped according to user’s demands. Server viewing based on group Servers are organized in different groups. User can do the grouping according to the demands. Security Actions taken on the server are authenticated based on the user privilege. http://www.tyan.com...
  • Page 33: Pre-Setup And Installation

    Configure Internal IP to be a valid IP under this subnet. Configure External IP to be the same as Internal IP. Firewall Firewall setup information: TSO MANAGER and CONSOLE will use the following 4 ports for firewall setup. TCP: 20010 21020 http://www.tyan.com...
  • Page 34: Installation

    Terminal”. You will see the screen with four choices: TSO Agent/TSO Manager/TSO Console/Exit. Type the number you want to install. Agent: - Select one of network interfaces to bundle (0 or 1). - Press Enter to complete installation. Manager: http://www.tyan.com...
  • Page 35 - Select one of external network interface to bundle. - Press Enter to complete installation. Console: - Select one of external network interfaces to bundle. - Press Enter to complete installation. 4. After finishing the installation, select Exit to leave the screen. http://www.tyan.com...
  • Page 36 17. After filling in user and company names, click “Next”. 18. Click “Next” after confirming the destination location of software. 19. Click “Yes” to reboot the system to initiate TSO Manager. 20. Click “Finish” to finish the TSO manager installation. http://www.tyan.com...
  • Page 37 2. Click on “INSTALL SUN JDK 1.4J_02”. 3. A Welcome message will appear. Click “Next”. 4. A License Agreement menu will show up. Click “Yes”. 5. After confirming the destination location of software, click “Next”. 6. Select all the components and then click “Next”. http://www.tyan.com...
  • Page 38: Run Tso

    Linux, go to /opt/tso/1.6/console, and run ./tsoxconsole In Windows, open start->programs->TSO In TSO login window, the first field is your management system IP, and the second field is OS user ID and password same as you login the OS that runs console . http://www.tyan.com...
  • Page 39 http://www.tyan.com...
  • Page 40: Tso Access

    Log in AGENT of the target system with the privilege ID and password • System Event Panel o Click “System Event Panel” to read all event log of the target system o “Clear” Icon Click the icon to clear system event log http://www.tyan.com...
  • Page 41 Sensor Alert Action - Check the desired alert method o Notification Configuration - Input a valid e-mail address - Input a valid SMTP server - Email information will be used if email event action is desired http://www.tyan.com...
  • Page 42: Out-Of-Band Access

    ID, user name and password. • Login SMDC MANAGER o Highlight the IP of the target system (Under Out-Of-Band) o Log in SMDC with the privilege ID and password o Privilege Names: Administrator, User, Callback, and Operator (case sensitive) http://www.tyan.com...
  • Page 43 - Click the icon with “Boot to BIOS” checked to get into target system BIOS after system is reset o “Cold Reset” Icon - Click the icon to cold reset SMDC o “Warm Reset” Icon - Click the icon to warm reset SMDC http://www.tyan.com...
  • Page 44 15 seconds. o “Refresh” Icon Click the icon to refresh system event log o “Clear” Icon Click the icon to clear system event log http://www.tyan.com...
  • Page 45 - Click the icon to review available users o “User Name” Bar/Drag Down - Click the button and scroll to the desired user o “Privilege” Field - Review privilege for corresponding user o “Change Password” Icon - Click the icon to update password http://www.tyan.com...
  • Page 46: Discovery Setting

    OS TCP/IP stack. You will need to enable the “Scan IP” function to discover the BMC. o If you install the TSO Agent on the server with BMC, you also can “Discover the BMC via Agent” while the OS is running. http://www.tyan.com...
  • Page 47: Chapter 6: Troubleshooting

    Solution: SMDC means System Management Daughter Card. It’s an embedded system, independent of the operating system, using the SMBus to monitor hardware sensors. TSO means Tyan System Operator. It is installed on different operating systems and allows remote or local monitoring.
  • Page 48 Question: What’s the M3291 Driver Solution: As IPMI is OS-independent, normally users don’t need load any driver when using M3291. But some times, when users want to use some in-band utility or application, IPMI driver is needed. Windows: M3291 can use the Intel IPMI Reference Driver. Users can get it at: http://www.intel.com/design/servers/ipmi/tools.htm...
  • Page 49 Select “Have Disk” Select “Browse” Select file “imbdrv.inf” Linux: M3291 can use the OpenIPMI driver in Linux Kernel. But as M3291 KCS port is CA8:CAC, version V33 is needed. modprobe ipmi_devintf modprobe ipmi_si If “ipmi_si” module load fail, you can try to add parameter:...
  • Page 50 Broadcom firmware to Nic Nvram. For dual port chip, current only one port supports IPMI, default is port 0 that is MAC small one. 2. Broadcom firmware download link: ftp://smdcGuest:53dcgop@66.122.195.2/smdc/M3291/firmware/Broadc 3. See readme. So far Broadcom only supports Dos utility to flash. http://www.tyan.com...
  • Page 51: Technical Support

    (which can have expensive consequences). If these options are not available for you then Tyan Computer Corporation can help. Besides designing innovative and quality products for over a decade, Tyan has continuously offered customers service beyond their expectations. Tyan's website (www.tyan.com) provides easy-to-access resources such as in-depth Linux Online...
  • Page 52 Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer. Dispose of used battery according to manufacturer instructions and in accordance with your local regulations. http://www.tyan.com...
  • Page 53: Appendix A: M3295 Opma Interface Pin Definition Table

    LRST_L DVI_TX_CLK_H LCLK DVI_TX_CLK_L RSVD DVI_DDC_DATA RSVD DVI_DDC_CLK RSVD MCARD_I2C_PR ANALOG_DDC_D IVATE0_SCL MCARD_I2C_PR ANALOG_DDC_CL IVATE0_SDA MCARD_I2C_IP ANALOG_RED MB_SCL MCARD_I2C_IP ANALOG_GREEN MB_SDA ANALOG_BLUE MCARD_I2C_SI DEBAND_NIC_S ANALOG_HSYNC MCARD_I2C_SI DEBAND_NIC_S ANALOG_VSYNC MCARD_I2C_SI DEBAND_NIC_A LERT RSVD MCARD_I2C_PR RSVD IVATE1_SCL MCARD_I2C_PR IVATE1_SDA MCARD_FAN_PW M_CPU http://www.tyan.com...
  • Page 54 SERIAL MCARD_RI0_L SEL3_L PORT MCARD_RXD0 MCARD_RXD_SO MCARD_TXD0 MCARD_CTS0_ MCARD_TXD_SO MCARD_RTS0_ FAULT_LED_L DEBUG DEBUG_PWR0 CHASSIS_ID_L DEBUG_PWR1 USB_P MCARD_ID0 USB_N MCARD_ID1 MCARD_PWRBTN MCARD_ID2 MCARD_RSTBTN MCARD_NMIBTN_ DEBUG_IF4 DEBUG DEBUG_IF5 MCARD_AUX_SO DEBUG_IF6 L_CTRL_L CTRL DEBUG_IF7 RSVD MCARD_LOCAL MCARD_RXD1 _LOCK_L CTRL MCARD_SYS_S MCARD_TXD1 ICMB http://www.tyan.com...
  • Page 55 SYS_ACPI_STATE MCARD_SCI_IN SYS_ACPI_STATE CTRL SYS_IO_EXP_INT RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD MCARD_TX_H VDD_3.3_DUAL MCARD_TX_L VDD_3.3_DUAL POWER VDD_3.3_DUAL MCARD_RX_H VDD_3.3_DUAL MCARD_RX_L POE_GND POE_PWR VDD_5_DUAL POE_PWR VDD_5_DUAL POE_GND LAN_BUSY_LED_ RSVD RSVD LAN_LINK_LED_L RSVD RSVD RSVD RSVD RSVD RSVD http://www.tyan.com...
  • Page 56: Appendix B: Opma Signals Grouped By Function

    Appendix B: OPMA Signals grouped by Function This table lists the signals that comprise the OPMA interface. You may also find this table from OPMA spec. http://www.amd.com/us-en/Processors/ProductInformation/0,,30_118_8796_12498,00.html http://www.tyan.com...
  • Page 57 http://www.tyan.com...
  • Page 58 http://www.tyan.com...
  • Page 59 +3.3VDC rail whereas earlier versions of the specification terminated some of these signals to the +5VDC rail. This specification is backward- compatible with motherboards that are compliant to the earlier termination specification. Document #: D1739 - 200 http://www.tyan.com...

This manual is also suitable for: