Operation/Care Of Your Appliance - Lennox Merit lmbv-36rmn Care And Operation Instructions Manual

Merit series b-vent gas fireplaces 36" lmbv models
Table of Contents

Advertisement

LENNOX HEARTH PRODUCTS • MERIT
OPERATION AND CARE OF YOUR APPLIANCE
Young children should be carefully supervised when they are in the
same room as the appliance. Toddlers, young children and others
may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict
access to a fireplace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room
and away from hot surfaces.
Les jeunes enfants devraient être surveillés étroitement lorsqu'ils se trou-
vent dans la même pièce que l'appareil. Les tout petits, les jeunes enfants
ou les adultes peuvent subir des brûlures s'ils viennent en contact avec
la surface chaude. Il est recommandé d'installer une barrière physique
si des personnes à risques habitent la maison. Pour empêcher l'accès
à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure
empêchera les tout petits, les jeunes enfants et toute autre personne à
risque d'avoir accès à la pièce et aux surfaces chaudes.
1. Appliance operation may be controlled
through a remotely located wall switch (not
supplied) or optional remote control kit. In
lieu of remote wall switch operation, the
appliance must be operated directly through
the controls located on the front of the valve
located within the control compartment un-
der the removable refractory access panel,
Figure 1.
Operation of millivolt and electronic gas
control systems are different. Before lighting
and operating your appliance determine if
you have a millivolt or electronic appliance.
Refer to Figure 1 to access the gas control
compartment below the lower refractory
panel.
Gas Controls
on Valve
Refractory
Access Panel
Figure 1
SIT Valve Shown
Millivolt appliances will be fitted with the gas
control valve shown in Figure 2. Appliances
with electronic systems will be fitted with the
electronic valve shown in Figure 3. Familiarize
yourself with the differing controls for the valve
your appliance uses.
SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • CARE AND OPERATION INSTRUCTIONS
®
WARNING
AvERTISSEMENT
To light millivolt appliances refer to the detailed
lighting instructions found in both English and
French on Pages 17 and 18 of these instructions.
Millivolt and electronic appliance lighting
instructions may also be found on the pull
out labels attached to the gas control valve
located within the gas control compartment.
Refer to Figure 2 to locate the spark igniter
used with your appliance.
If your appliance is equipped with an optional
remote wall switch or remote control kit the
appliance main burner may be turned on and
off with the wall switch or remote control. If the
appliance is not equipped with a wall or remote
control, the main burner must be turned off and
on with the gas control knob. Turn the knob
counter-clockwise from the PILOT position
to ON to light the main burner, and clockwise
from ON to PILOT to turn off the main burner.
Piezo
To light electronic appliances refer to the
Igniter
detailed lighting instructions found in both
English and French on Pages 19 and 20 of
these instructions respectively. Millivolt and
electronic appliance lighting instructions may
also be found on the pull out labels attached
to the gas control valve located within the gas
control compartment.
If your appliance is equipped with an optional
remote wall switch or remote control kit the
appliance main burner may be turned on and
off with the wall switch or remote control. If the
appliance is not equipped with a wall switch or
remote control, the main burner must be turned
off and on with the gas control switch. Toggle
the switch from ON to OFF to operate the main
burner from ON to OFF.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Gas valve Diagrams
See Figure 2 for Millivolt models and Figure 3
For Electronic Models.
Manifold Pressure Tap
Inlet Pressure Tap
A
E
Pilot Adjustment
Main Gas Control Knob
Screw
OFF/PILOT/ON
SIT Millivolt Gas Valve
Figure 2 -
Honeywell Electronic
Figure 3
Gas Valve
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This
is due to the "burn-in" of internal paints
and lubricants used in the manufacturing
process.
3. Keep the lower control compartment clean
by vacuuming or brushing at least twice a
year. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
materials, etc. It is important that control
compartments, burners and circulating air
passageways of the appliance be kept clean
and clear of obstruction of ventilating and
combustion air.
4. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-
lighting, refer to the lighting instructions
in this manual. Instructions are also found
on a pull-out panel located on the floor of
the appliance.
5. Always keep the appliance area clear and
free from combustible materials, gasoline
and other flammable vapors and liquids.
6. Remember, Millivolt appliances have a
continuous burning pilot flame. Exercise cau-
tion when using products with combustible
vapors.
Piezo
Igniter
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merit lmbv-36rmpLmbv-36renMerit lmbv-36r

Table of Contents