SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • CARE AND OPERATION INSTRUCTIONS
®
MANUALLY-RESET bLOCKED FLUE SAFETY
SWITCH
This appliance is equipped with a manually-reset
blocked flue safety switch. Refer to Figure 7
for its location. If during appliance operation,
the flame goes out (independently of the burner
on/off wall switch), it may be due to the opera-
tion of this safety limit switch. First allow the
appliance to cool, then reset the safety switch
by pushing the red reset button on the back
of the switch.
Limit
Switch
Screws
Fireplace Front
Figure 7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
CAUTION: THE ELECTRONIC APPLIANCE
SHOULD bE TURNED OFF bEFORE REMOvING
THE LIMIT SWITCH.
To access the safety limit switch reset button,
remove the two screws. Pull out limit switch
with low voltage wires attached, push the reset
button, then reinstall the limit switch. At this
time turn the electronic appliance back on.
The appliance should then relight and remain
lit. If this does not occur, turn off the appliance
and call a qualified service technician.
Manual Reset Limit Switch
Left Side Refractory Panel
Lintel
Extention