A
If the hose is long and
the room temperature
low, the moisture might
condense to water
inside the hose. This is
an unavoidable natural
phenomenon. To
prevent this water from
Iying in the hose or
flowing back into the tumble dryer, it is
advisable to drill a small hole (via. 3 mm) in the
lowest point of the hose and to place a small
container below it. (See picture, point B).
Once connected to the dryer, run the vent hose
to the desired outlet point, ensuring that the
run's overall length is less than 2 m, and that it
contains no more than two bends. As to the
outlet itself, if you have decided on a fixed wall/
window grille, a good local builder's merchant
should be able to supply you with the necessary
fittings and installation advice.
Warning!
It is important not to
connect the vent hose
to, for example, a
cooker hood, or a
chimney or flue pipe
designed to carry the
exhaust from a fuel
burning appliance.
Note that to avoid con-
densation problems, it is essential that the dryer
be fitted with the flexible hose to carry its "ex-
haust" at least beyond the kitchen units; pref-
erable outside the kitchen. In order to prevent
the appliance from overheating, it is important
that the steam exhaust is unobstructed. There-
fore, in case of a permanent hose fitted to an
www.zanussi.com
exterior wall or ceiling, it must be ensured an ex-
haust capacity of at least 150 m3/h. If the dryer
is fitted next to kitchen units, make sure that the
A
vent hose is not squashed. If the hose is partial-
ly squashed, drying efficiency will be reduced,
resulting in longer drying times and higher ener-
gy consumption. If the hose is completely
squashed, the safety cut-outs with which the
machine is fitted may operate. When operating
the tumble dryer, the room temperature must
not be lower than +5°C and higher than +35°C,
as it may affect the performance of the appli-
ance.
Electrical connection
Details on mains voltage, type of current and the
fuses required should be taken from the rating
B
plate. The rating plate is fitted near the loading
aperture (see "Product description" chapter).
Connect the machine to an earthed socket, in
accordance with current wiring regulations.
Warning! The manufacturer declines
any responsibility for damage or
injury through failure to comply with the
above safety precautions.
Should the appliance power supply cable
need to be replaced, this must be carried
out by an authorised service engineer or a
qualified electrician. .